2014
DOI: 10.1016/j.remn.2013.03.009
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo simulation of the basic features of the GE Millennium MG single photon emission computed tomography gamma camera

Abstract: Objective To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…Both the simulated energy and planar spatial resolutions were found to show close agreement. Sensitivity measurements were less well matched, however, GATE has been known to overestimate the sensitivity values because the models often do not account for the dead spaces between PMTs 16. The number of counts, and therefore the sensitivity, detected on head 3 was higher than head 1 because the sensitivity phantom stilts were placed on head 3 and so the source was slightly closer to it than head 1.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Both the simulated energy and planar spatial resolutions were found to show close agreement. Sensitivity measurements were less well matched, however, GATE has been known to overestimate the sensitivity values because the models often do not account for the dead spaces between PMTs 16. The number of counts, and therefore the sensitivity, detected on head 3 was higher than head 1 because the sensitivity phantom stilts were placed on head 3 and so the source was slightly closer to it than head 1.…”
Section: Discussionmentioning
confidence: 99%
“…As the GATE simulation detects the γ photons interacting with the crystal directly, we did not have to create a model for the light guide, the 60 PMTs and the electronics at the back of the detector head. Instead, we filled the remaining area of the detector head (between the crystal and the shielding) with a single block of glass, as used by Vieira et al 16. This approach is deemed suitable for low-energy applications as it accounts for the scatter from the back-compartment whilst providing similar results to a more detailed model 26.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Similar studies have been carried out on SPECT scanners. [23][24][25] Such studies have been occasionally conducted on multimodality scanners including PET/magnetic resonance [26] and PET/SPECT/CT. [27] In the present study, the GATE simulation code was used for performance assessment and validation of the GE Discovery PET/CT 690 VCT scanner.…”
Section: Introductionmentioning