Abstract:This is a copy of the published version, or version of record, available on the publisher's website. This version does not track changes, errata, or withdrawals on the publisher's site.
“…These are briefly described in the subsequent subsections together with an update on their integration procedure. A detailed description of all MOONS components can be found in [1] and in dedicated papers for the different subsystems [2], [3], [4], [5], [6], [7], [8], [9]. The MOONS RFE is mounted to the telescope and contains the focal plate and fibre positioning system used to align the optical fibres to their desired on-sky locations.…”
Section: Moons Technical Overviewmentioning
confidence: 99%
“…The final integration of the metrology system is done once the focal plate is installed in the RFE and the endto-end system can be fully verified. Further details on the MOONS metrology system can be found in [8].…”
This is a copy of the published version, or version of record, available on the publisher's website. This version does not track changes, errata, or withdrawals on the publisher's site.
“…These are briefly described in the subsequent subsections together with an update on their integration procedure. A detailed description of all MOONS components can be found in [1] and in dedicated papers for the different subsystems [2], [3], [4], [5], [6], [7], [8], [9]. The MOONS RFE is mounted to the telescope and contains the focal plate and fibre positioning system used to align the optical fibres to their desired on-sky locations.…”
Section: Moons Technical Overviewmentioning
confidence: 99%
“…The final integration of the metrology system is done once the focal plate is installed in the RFE and the endto-end system can be fully verified. Further details on the MOONS metrology system can be found in [8].…”
This is a copy of the published version, or version of record, available on the publisher's website. This version does not track changes, errata, or withdrawals on the publisher's site.
“…MOONS has a camera-based metrology system capable of providing feedback on the location of the fibre positioners, which is described in [3]. The metrology system must be capable of detecting all the fibre positioners and determining their locations and orientations unambiguously to within the same positioning tolerance as the positioners themselves.…”
“…If nothing has changed since they were parked, the flow will pass through the upper part of the "Initialise FP" box of Figure 13; and initialisation consists of finding the datum reference point. A metrology measurement [3] can be used to determine the locations of the fibre positioners after a fault. The "Recover FPUs" box in Figure 13 shows the procedure needed to bring fibre positioners back to a SAFE state after a fault.…”
Section: Initialisation and Fault Recoverymentioning
confidence: 99%
“…The MOONS metrology camera [3] can't be used to measure synchronisation because it cannot achieve the required time resolution, even if the camera is operated in video mode. The time measurement requirements were achieved by using a 16-channel logic analyser to view and measure the relative synchronisation timings between the initial stepper motor electrical movement pulses across up to 16 FPUs at once.…”
This is a copy of the published version, or version of record, available on the publisher's website. This version does not track changes, errata, or withdrawals on the publisher's site.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.