Mortero geopolimérico para uso potencial como recubrimiento en concreto

Abstract: ResumenSe sintetizaron dos morteros geopoliméricos basados en Metacaolín y residuo de ladrillo, modificados con adiciones orgánicas e inorgánicas para ser utilizados como potenciales recubrimientos sobre concretos. Se evaluaron sus propiedades en estado fresco (fluidez, tiempo de fraguado) y en estado endurecido (resistencia a la compresión y tracción, absorción, porosidad y conductividad térmica). Los resultados muestran la viabilidad de producir morteros Clase R1 y R2 en concordancia con la Norma EN 1504-3 e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 17 publications
(21 reference statements)
0
3
0
Order By: Relevance
“…International standards do not define limit values for density, making it difficult to analyze this parameter. However, authors report density ranging from 1.80 to 2.10 g/cm³ for cementitious mortars [ 19 , 21 , 28 , 29 ] and activated alkali [ 27 , 30 , 31 ] with satisfactory adhesion values. Therefore, these values might be used for comparison.…”
Section: Introductionmentioning
confidence: 99%
“…International standards do not define limit values for density, making it difficult to analyze this parameter. However, authors report density ranging from 1.80 to 2.10 g/cm³ for cementitious mortars [ 19 , 21 , 28 , 29 ] and activated alkali [ 27 , 30 , 31 ] with satisfactory adhesion values. Therefore, these values might be used for comparison.…”
Section: Introductionmentioning
confidence: 99%
“…Also, when the percentage of titanium dioxide (TiO2) increases, the compressive strength decreases from 214 to 158 kg/cm2. It is important to mention that even though there is a decrease in strength, these data are positive as the expected strength was 145 kg/cm2 as well as in contrast to other authors who obtained lower strengths close to the above mentioned as 10.96 Mpa or 111.82 kg/cm2 as concluded by (Oviedo Katherine & Mejia Ruby, 2019). Therefore, the correlation between TiO2 percentage and air pollution reduction is direct, while the correlation between TiO2 percentage and compressive strength is indirect.…”
mentioning
confidence: 56%
“…Concluding that when longitudinal cracks appear in the cladding, the safety of the structure is seriously endangered". Also [29] concluded that it is necessary to advance in the evaluation of the coating adhesion and the strength of concrete walls to make a more accurate classification." [25] mentions that the State is responsible for assisting citizens in various elements, such as access to basic services, promotion of economic dependence, provision of decent employment, number of inhabitants in residential areas, and social development, which increases the quality of life of people.…”
Section: Fc N 𝑑 𝑠mentioning
confidence: 99%