2020
DOI: 10.3390/s20102797
|View full text |Cite
|
Sign up to set email alerts
|

Moxifloxacin Hydrochloride Electrochemical Detection at Gold Nanoparticles Modified Screen-Printed Electrode

Abstract: It appeared that either the carbon paste or the screen-printed carbon electrodes that were modified with gold nanoparticles (AuNPs) gave rise to the largest current responses after a rapid screening of various nanomaterials as modifiers of carbon composite electrodes in view of designing an electrochemical sensor for Moxifloxacin Hydrochloride (Moxi). The screen-printed electrode (SPE) support was preferred over the carbon paste one for its ability to be used as disposable single-use sensor enabling the circum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 26 publications
(11 citation statements)
references
References 70 publications
0
11
0
Order By: Relevance
“…2 Moxifloxacin Hydrochloride (MOX) is an antimicrobial of low toxicity and has an effect against gram (+ve), and gram (-ve) bacteria. 3 MOX is either given as an intracameral injection or topically. However, the intracameral injection may cause corneal endothelial toxicity and toxic anterior segment syndrome.…”
Section: Introductionmentioning
confidence: 99%
“…2 Moxifloxacin Hydrochloride (MOX) is an antimicrobial of low toxicity and has an effect against gram (+ve), and gram (-ve) bacteria. 3 MOX is either given as an intracameral injection or topically. However, the intracameral injection may cause corneal endothelial toxicity and toxic anterior segment syndrome.…”
Section: Introductionmentioning
confidence: 99%
“…6) can be represented by the linear equation: Figure 6 inset shows the corresponding differential pulse curves for increasing vitamin B 6 concentrations (from 8.88 up to 1000.0 µM) in 0.1 M of PBS (pH 6.0) and scan rate 0.01 Vs −1 using IONCPE. Limit of quantification (LOQ) and limit of detection (LOD) were calculated by the following equations [72]:…”
Section: Calibration Curve Studymentioning
confidence: 99%
“…Carboxylated MWCNTs decorated with AuNPs using ethylenediamine as a cross-linker were drop-casted on SPE and applied for electrochemical determination of amoxicillin combining the good electron transfer property and catalytic property of the two nanomaterials [ 276 ]. AuNPs have been electrochemically deposited on SPE (with spherical shape and size between 13–58 nm) and applied for moxifloxacin hydrochloride detection with good performance [ 277 ]. A low-cost SPE modified with fullerene, reduced graphene oxide and nafion has been elaborated in order to evaluate metronidazole with high stability, repeatability, reproducibility, fast response and low cost, performance which is due to the electrocatalytic synergic effect of the nanomaterials [ 278 ].…”
Section: Metal Nanoparticles and Carbon-based Nanomaterials In (Bio)sensors Designmentioning
confidence: 99%