2008
DOI: 10.1007/s11547-008-0289-y
|View full text |Cite
|
Sign up to set email alerts
|

MR imaging-guided 10-gauge vacuum-assisted breast biopsy: histological characterisation

Abstract: MRI-guided biopsy of breast lesions using a handheld vacuum-assisted device is a safe and effective method for the workup of suspicious lesions seen on breast MRI alone.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
17
1
3

Year Published

2009
2009
2017
2017

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(23 citation statements)
references
References 13 publications
2
17
1
3
Order By: Relevance
“…Dopo aver rimosso il mandrino previa anestesia cutanea (lidocaina cloridrato diluita al 2%, 10 cc) e incisione con bisturi, è stata inserita la sonda per i prelievi. Il prelievo è stato compiuto utilizzando un dispositivo palmare dotato di sistema generante vuoto a pressione, alimentato da batteria al litio e controllato da tastiera integrata a sfi oramento (VACORA VAB system, BARD France SAS, Voisins Le Bretonneux, Francia) [15,16]. I prelievi sono stati eseguiti con ago da 10 gauge per esame istologico secondo multipli giri coassiali, generalmente in numero di tre.…”
Section: Mr-guided Biopsyunclassified
See 1 more Smart Citation
“…Dopo aver rimosso il mandrino previa anestesia cutanea (lidocaina cloridrato diluita al 2%, 10 cc) e incisione con bisturi, è stata inserita la sonda per i prelievi. Il prelievo è stato compiuto utilizzando un dispositivo palmare dotato di sistema generante vuoto a pressione, alimentato da batteria al litio e controllato da tastiera integrata a sfi oramento (VACORA VAB system, BARD France SAS, Voisins Le Bretonneux, Francia) [15,16]. I prelievi sono stati eseguiti con ago da 10 gauge per esame istologico secondo multipli giri coassiali, generalmente in numero di tre.…”
Section: Mr-guided Biopsyunclassified
“…After removing the stylet, the site was anaesthetised (10 cc 2% lidocaine hydrochloride) and incised with a scalpel, and the biopsy probe was inserted. Biopsies were obtained using a handheld device equipped with a vacuum-generating system powered by a lithium battery and controlled through an integrated touch pad (VACORA VAB system, BARD France SAS, Voisins Le Bretonneux, France) [15,16]. Samples were collected with a 10-gauge needle with multiple (usually three) coaxial passes.…”
Section: Mr-guided Biopsymentioning
confidence: 99%
“…[11][12][13][14][15][16] and the United States 17-21 to avoid unnecessary surgical biopsy. In contrast, US-guided biopsy is performed for MRI-detected lesions in Japan.…”
Section: Incidence Of Malignancies In Various Groupsmentioning
confidence: 99%
“…MX guidance was reserved for microcalcifications, whereas MRI guidance was used for lesions visible on MRI alone [11][12][13]. Lesions were located using methods previously described in the literature for each of the imaging modalities [14][15][16].…”
Section: Materiali E Metodimentioning
confidence: 99%
“…La guida stereotassica è stata riservata ai casi di microcalcificazioni, mentre quella RM per lesioni rilevate alla sola risonanza magnetica [11][12][13]. La localizzazione delle lesioni è avvenuta per ogni guida strumentale con modalità già descritte in letteratura [14][15][16].…”
Section: Materiali E Metodiunclassified