2013
DOI: 10.1002/9781118761281
|View full text |Cite
|
Sign up to set email alerts
|

MRI Techniques

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…2. The bc faces are conspicuous by absence, being ⊥ B 1 . The resulting MRI tunnel supplies a visual of peering at a virtual absence of EM fields in the interior of a metallic conductor, since the center of the strip is at least (2.25mm/2)/(6.9µm) = 163 skin-depths away from the surface (and hence any EM fields and the MR signal would be virtually buried in noise; see Fig.…”
Section: Mrimentioning
confidence: 99%
See 1 more Smart Citation
“…2. The bc faces are conspicuous by absence, being ⊥ B 1 . The resulting MRI tunnel supplies a visual of peering at a virtual absence of EM fields in the interior of a metallic conductor, since the center of the strip is at least (2.25mm/2)/(6.9µm) = 163 skin-depths away from the surface (and hence any EM fields and the MR signal would be virtually buried in noise; see Fig.…”
Section: Mrimentioning
confidence: 99%
“…2a, the signal intensity from the ab faces can be written as (see Eq. (S8)) S ab (x, y) ∝ dx dy dz = dx dy 2δ eff (1) with dx dy dz denoting elemental volume of the metal, and δ eff is the effective subsurface depth that would account for the MR signal in the absence of B 1 decay (see Eq. (S7) and Fig.1).…”
Section: Intensity Ratio Formulae For Bulk Metal Mri and Csimentioning
confidence: 99%
“…The simulation accuracy can be guaranteed even with large-size meshes. Besides, the energies of most of the gradient pulses concentrate at low-frequency band, such as GE (gradient echo) and SE (spin echo) [ 7 , 22 , 23 ]. Therefore, the investigation in this work focuses on the frequency band from 100 Hz to 1000 Hz, which can present a more clear observation of the noise reduction scheme effect and the method may still suit the high-frequency condition.…”
Section: Discussionmentioning
confidence: 99%
“…MRI is a household name as a diagnostic tool in the medical field, 10,11 with an impressive resume in many other fields, including the study of materials, [12][13][14][15] corrosion of metals, monitoring batteries and supercapacitors. 16,17 However, historically, MRI of bulk metals has been very rare, limited to specialized cells using r.f.…”
Section: Introductionmentioning
confidence: 99%