2022
DOI: 10.1055/a-1750-8800
|View full text |Cite
|
Sign up to set email alerts
|

Mucosal defect closure using a calibrated, small-caliber-tip, transparent hood after colorectal endoscopic submucosal dissection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
10
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 5 publications
(5 reference statements)
0
10
0
Order By: Relevance
“…To address the aforementioned limitations of the E-Loc technique, we developed the reopenable clip (SureClip; Micro-Tech Co. Ltd., Nanjing, China) over the line method (ROLM), which can be used for defect closure without creating an SDS. 94,[102][103][104] In ROLM, a clip with a line is inserted through one of the holes of the reopenable clip to grasp the contralateral normal mucosal edge and the muscularis propria. ROLM can be performed after ER and does not require the removal of the scope or special devices (Fig.…”
Section: Mucosal Defect Closure Methods Designed To Reduce Sdsmentioning
confidence: 99%
“…To address the aforementioned limitations of the E-Loc technique, we developed the reopenable clip (SureClip; Micro-Tech Co. Ltd., Nanjing, China) over the line method (ROLM), which can be used for defect closure without creating an SDS. 94,[102][103][104] In ROLM, a clip with a line is inserted through one of the holes of the reopenable clip to grasp the contralateral normal mucosal edge and the muscularis propria. ROLM can be performed after ER and does not require the removal of the scope or special devices (Fig.…”
Section: Mucosal Defect Closure Methods Designed To Reduce Sdsmentioning
confidence: 99%
“…This continuous saline infusion facilitates smooth dissection by preventing the obstruction of the endoscopic field of vision by gas. Furthermore, the saline immersion technique softens the mucosa and muscles, enabling easy closure of the defect using the reopenable clip-over-line method [5]. The gas-free saline-immersion technique for ESD is a feasible method with no CO 2 gas emission during saline immersion.…”
Section: E1039mentioning
confidence: 99%
“…Although various methods have been devised for tumor dissection, none have reported visualization of the tumor border on the appendiceal side prior to ESD. We have previously reported a calibrated, small‐caliber tip, transparent hood (CAST hood; TOP, Tokyo, Japan) that enables accurate fibrotic dissection 2,3 . This report presents a technique using the CAST hood that allows visualization and complete resection of the border of a tumor located at the appendiceal orifice (Fig.…”
Section: Brief Explanationmentioning
confidence: 99%
“…We have previously reported a calibrated, small-caliber tip, transparent hood (CAST hood; TOP, Tokyo, Japan) that enables accurate fibrotic dissection. 2,3 This report presents a technique using the CAST hood that allows visualization and complete resection of the border of a tumor located at the appendiceal orifice (Fig. 1, Video S1).The patient had a Paris type 0-IIa, granular type, laterally spreading tumor at the appendiceal orifice.…”
mentioning
confidence: 99%