2011 IEEE SENSORS Proceedings 2011
DOI: 10.1109/icsens.2011.6127390
|View full text |Cite
|
Sign up to set email alerts
|

Multi-axis flexible force sensor for tactile display

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…Previous literature has not referred to the viscous response of their sensor in detail [18][19][20][21][22][23][24][25]33], although Laszczak et al [33] possibly hinted at this based on the statement "a specific tare load was applied to the sensor for 30 s… this strategy minimized a possible transient response resulting from the viscoelastic behaviour of the Elastomer". Unfortunately, details about the tare load were not described, nor were details about the effectiveness of pre-loading in their experiment, making direct comparison to their results difficult.…”
Section: Viscous Sensor Response and Pre-loadingmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous literature has not referred to the viscous response of their sensor in detail [18][19][20][21][22][23][24][25]33], although Laszczak et al [33] possibly hinted at this based on the statement "a specific tare load was applied to the sensor for 30 s… this strategy minimized a possible transient response resulting from the viscoelastic behaviour of the Elastomer". Unfortunately, details about the tare load were not described, nor were details about the effectiveness of pre-loading in their experiment, making direct comparison to their results difficult.…”
Section: Viscous Sensor Response and Pre-loadingmentioning
confidence: 99%
“…Additionally, insertion of components with an elastic modulus that is dissimilar to UHMWPE may cause stress risers and promote damage of the bearing [16] , whereas capacitive sensors can be designed to be more compliant, because sensor materials and electrode construction can be adjusted to closely match the mechanical properties of the host component. Polymer based capacitive sensors have previously been used to measure forces [18][19][20][21][22][23][24][25] but never to measure forces within joints and they have never been incorporated into industrial production process used in producing polyethylene bearings.…”
Section: Introductionmentioning
confidence: 99%