2002
DOI: 10.1016/s0720-048x(01)00457-0
|View full text |Cite
|
Sign up to set email alerts
|

Multi-centre clinical study evaluating the efficacy of SonoVue™ (BR1), a new ultrasound contrast agent in Doppler investigation of focal hepatic lesions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
55
0
1

Year Published

2005
2005
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 108 publications
(57 citation statements)
references
References 11 publications
1
55
0
1
Order By: Relevance
“…In our study, we used SonoVue, a second-generation ultrasound contrast agent. SonoVue is an intravascular agent (Leen et al 2002) and the mechanism underlying liver parenchymal enhancement remains unknown (Leen et al 2006). It has been suggested that the persistence of the agent within the healthy liver may be a result of the very slow flow within the sinusoids (Leen et al 2006).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In our study, we used SonoVue, a second-generation ultrasound contrast agent. SonoVue is an intravascular agent (Leen et al 2002) and the mechanism underlying liver parenchymal enhancement remains unknown (Leen et al 2006). It has been suggested that the persistence of the agent within the healthy liver may be a result of the very slow flow within the sinusoids (Leen et al 2006).…”
Section: Discussionmentioning
confidence: 99%
“…SonoVue (Bracco Imaging, Milan, Italy) is an intravascular ultrasound contrast agent that consists of stabilized microbubbles of a sulfur hexafluoride gas (Leen et al 2002). Experimental evidence in rats has shown that microbubble agents containing perfluorocarbon gas, such as SonoVue, enhance the healthy liver by virtue of its slow flow within the sinusoids (Kono et al 2002).…”
Section: Introductionmentioning
confidence: 99%
“…Recent studies have evaluated the revenue of enhanced Doppler in differentiating benign from malignant hepatic lesions 25 and breast tumours. 26 Further research should be performed to investigate the diagnostic accuracy of contrast-enhanced Doppler ultrasound in differentiating benign from malignant SG tumours compared with the baseline (pre-dosing) performance.…”
Section: Pulsatility Indexmentioning
confidence: 99%
“…The microbubbles are isotonic to human plasma and stable and resistant to pressure. SonoVue improves the display of focal tumor vascularity and normal parenchymal liver vascularity [16] . Sonazoid is another second-generation UCA solely available in Japan.…”
Section: Ultrasound Contrast Agents (Ucas) and Contrast-specific Techmentioning
confidence: 99%