2016
DOI: 10.1016/j.ijrobp.2016.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Multi-institutional Validation Study of Commercially Available Deformable Image Registration Software for Thoracic Images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
104
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 96 publications
(106 citation statements)
references
References 35 publications
2
104
0
Order By: Relevance
“…Nevertheless, the systems failed to map CTV with acceptable accuracy from the DVF2 data set: DSC and MDC were, respectively, 0.52 and 5.45 mm, and thus highlighting the importance of the type of deformation. Differently from other studies published during which DIR was performed between the inhale and exhale phases with DVF distributed on large volumes with smooth gradients, in this case, the deformation was driven by a shrinking volume that generates high localized deformations in 4π geometry. This situation is critical for the regularization term of the algorithm whose role is to smooth and maintain the DIR locally invertible.…”
Section: Discussionmentioning
confidence: 88%
See 2 more Smart Citations
“…Nevertheless, the systems failed to map CTV with acceptable accuracy from the DVF2 data set: DSC and MDC were, respectively, 0.52 and 5.45 mm, and thus highlighting the importance of the type of deformation. Differently from other studies published during which DIR was performed between the inhale and exhale phases with DVF distributed on large volumes with smooth gradients, in this case, the deformation was driven by a shrinking volume that generates high localized deformations in 4π geometry. This situation is critical for the regularization term of the algorithm whose role is to smooth and maintain the DIR locally invertible.…”
Section: Discussionmentioning
confidence: 88%
“…Analogous conclusions were drawn by the second study, wherein all the algorithms reported sub‐voxel mean TREs in lung, but only a minority of them succeeded in obtaining similar accuracy in the liver and the potential for large maximum errors was highlighted. Finally, significant intercenter variability caused by the procedures adopted were reported by Kadoya …”
Section: Discussionmentioning
confidence: 93%
See 1 more Smart Citation
“…Kadoya et al [32] published a multi-institutional comparison study using 10 thoracic cancer patients with manually defined anatomical landmarks. Each institution reported DIR results of 10 patients’ data using commercial DIR softwares—RayStation (RaySearch Laboratories, Stockholm, Sweden), MIM Software (Cleveland, OH, USA), and Velocity (Varian Medical Systems, Palo Alto, CA, USA).…”
Section: Validation Of Dir Algorithmmentioning
confidence: 99%
“…To improve DIR accuracy, hybrid DIR has been recently developed and implemented in RayStation [27]. This has the potential to improve DIR accuracy, even with large interfractional organ motion [28]. Till now there has been no data showing the performance of hybrid DIR between planning CT and CBCT for the pelvic region.…”
Section: Introductionmentioning
confidence: 99%