2019
DOI: 10.3389/fmicb.2019.00562
|View full text |Cite
|
Sign up to set email alerts
|

Multi-Laboratory Validation of a Loop-Mediated Isothermal Amplification Method for Screening Salmonella in Animal Food

Abstract: Loop-mediated isothermal amplification (LAMP) has gained wide popularity in the detection of Salmonella in foods owing to its simplicity, rapidity, and robustness. This multi-laboratory validation (MLV) study aimed to validate a Salmonella LAMP-based method against the United States Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) Chapter 5 Salmonella reference method in a representative animal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

1
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(12 citation statements)
references
References 30 publications
1
11
0
Order By: Relevance
“…LAMP screening. After overnight incubation at 358C in BPW or LB, aliquots (1 mL) of each test portion were removed from the filtered side of the bag, and DNA was extracted using the PrepMan ultra sample preparation reagent (Thermo Fisher Scientific, Waltham, MA (11,17)). In the LAMP assay, 2 μL of the DNA extracts was used, and the assay was repeated once independently.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…LAMP screening. After overnight incubation at 358C in BPW or LB, aliquots (1 mL) of each test portion were removed from the filtered side of the bag, and DNA was extracted using the PrepMan ultra sample preparation reagent (Thermo Fisher Scientific, Waltham, MA (11,17)). In the LAMP assay, 2 μL of the DNA extracts was used, and the assay was repeated once independently.…”
Section: Methodsmentioning
confidence: 99%
“…The LAMP assay was conducted as described previously (10,11,17); the only exception was that a new isothermal master mix (ISO-004, OptiGene Ltd., West Sussex, UK) was used side by side with the original one (ISO-001, OptiGene). The LAMP reagent mixture in a total volume of 25 μL contained 13 isothermal master mix (ISO-001 or ISO-004), 13 primer mix (0.1 μm each of outer primer [Sal4-F3 and Sal4-B3], 1.8 μm each of inner primer [Sal4-FIP and Sal4-BIP], and 1 μm each of loop primer [Sal4-LF and Sal4-LB]; Integrated DNA Technologies, Coralville, IA), and 2 μL of DNA template.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Previously, Salmonella spp. contamination of animal and poultry feed has received most of the attention and remains a current focus for the development of detection methods suited explicitly for feeds as well as the pursuit of more effective control measures (12,26,30,(45)(46)(47)(48)(49)(50)(51)(52)(53). Numerous Salmonella spp.…”
Section: Biological Contamination Of Feedsmentioning
confidence: 99%