2022
DOI: 10.1016/j.brs.2021.11.014
|View full text |Cite
|
Sign up to set email alerts
|

Multi-locus transcranial magnetic stimulation system for electronically targeted brain stimulation

Abstract: Background Transcranial magnetic stimulation (TMS) allows non-invasive stimulation of the cortex. In multi-locus TMS (mTMS), the stimulating electric field (E-field) is controlled electronically without coil movement by adjusting currents in the coils of a transducer. Objective To develop an mTMS system that allows adjusting the location and orientation of the E-field maximum within a cortical region. Methods We designed and manufactured a pl… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
34
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

4
3

Authors

Journals

citations
Cited by 45 publications
(34 citation statements)
references
References 38 publications
0
34
0
Order By: Relevance
“…In this work, we determined the stimulation location and intensity manually based on visual inspection of averaged TEPs [ 29 ]. We believe that the whole procedure can, however, be automated by combining the presented closed-loop algorithm, for example, with a 5-coil multi-locus TMS system that allows adjusting the stimulation location and orientation without coil movement [ 54 ]. An advanced algorithmic implementation may thus make visual evaluation and manual assessment redundant in the future.…”
Section: Discussionmentioning
confidence: 99%
“…In this work, we determined the stimulation location and intensity manually based on visual inspection of averaged TEPs [ 29 ]. We believe that the whole procedure can, however, be automated by combining the presented closed-loop algorithm, for example, with a 5-coil multi-locus TMS system that allows adjusting the stimulation location and orientation without coil movement [ 54 ]. An advanced algorithmic implementation may thus make visual evaluation and manual assessment redundant in the future.…”
Section: Discussionmentioning
confidence: 99%
“…The 2-coil transducer has a size similar to that of commercial figure-of-eight TMS coils and only half the size (150 mm) of our other mTMS transducers: the 2-coil transducer for shifting the stimulation locus within a line segment [12] and the 5-coil mTMS transducer that can shift and rotate the peak E-field within a cortical region [14]. The recently developed 5-coil mTMS 21 transducer comprises a similar combination of two perpendicular figure-of-eight coils to rotate the E-field orientation electronically; however, the large size (300 mm × 300 mm) prevents its use in cortical areas with restricted space.…”
Section: Mtms Transducermentioning
confidence: 99%
“…If desired, this difference can be eliminated in future models by designing the bottom coil so that its focality matches the other coil's pattern [44]. The possibility to use 3D-printed formers might ease the manufacturing of transducers with more complicated winding patterns, such as those reported by Deng et al [45] and mTMS transducers with more coils [12,14].…”
Section: Mtms Transducermentioning
confidence: 99%
See 2 more Smart Citations