2003
DOI: 10.1016/s0142-0615(02)00101-1
|View full text |Cite
|
Sign up to set email alerts
|

Multi-objective design of damping controllers of FACTS devices via mixed H2/H∞ with regional pole placement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
20
0

Year Published

2005
2005
2022
2022

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(20 citation statements)
references
References 19 publications
0
20
0
Order By: Relevance
“…Choosing the best input signal is based on earlier studies in [15,32,33]. Therefore the generator speed is considered as input to PSS in a two-area four-machine system and the input to the supplementary controller of SVC is the active power flow in line 1 -27.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Choosing the best input signal is based on earlier studies in [15,32,33]. Therefore the generator speed is considered as input to PSS in a two-area four-machine system and the input to the supplementary controller of SVC is the active power flow in line 1 -27.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…The simple conventional PI controllers, designed based on the linearized model of the system at the certain operating points, do not provide an appropriate dynamic response to various loading conditions and disturbances [6]. It can be shown that adding optimal robust auxiliary damping signals to the conventional PI controllers, is the effective strategy for stability enhancement [13]. The block diagram of the conventional PI and its damping controller for the series branch of the UPFC is shown in Fig.…”
Section: Upfc Damping Controllermentioning
confidence: 99%
“…Also, in ∞ H control synthesis, there exist some conflicts between various weighting functions selection [12][13][14]. On the other hand, the H 2 control algorithm presents a more suitable performance on system transient behavior.…”
Section: Damping Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…A robust mixed H 2 /H ∞ based LFC of a deregulated power system including superconducting magnetic energy storage has been proposed in [28]. For other works regarding the application of mixed H 2 /H ∞ control into MGs, readers can refer to [29,30], etc. It is notable that, although a mixed H 2 /H ∞ control technique has been widely used in conventional power systems, there has been little work applying such control schemes into the field of EI.…”
Section: Introductionmentioning
confidence: 99%