2016
DOI: 10.1016/j.enconman.2016.09.082
|View full text |Cite
|
Sign up to set email alerts
|

Multi-objective energy management optimization and parameter sizing for proton exchange membrane hybrid fuel cell vehicles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
77
0
1

Year Published

2016
2016
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 241 publications
(78 citation statements)
references
References 22 publications
0
77
0
1
Order By: Relevance
“…Then we can get a description of the battery consumption. It is remarkable that in , authors also use equivalent hydrogen consumption model. rightΔξleft=ΔAhzA1zeEa+B·CRzRTBatξz1zrightrightΔAhleft=13600tptp+1|Ibat|dt. …”
Section: Optimal Energy Managementmentioning
confidence: 99%
“…Then we can get a description of the battery consumption. It is remarkable that in , authors also use equivalent hydrogen consumption model. rightΔξleft=ΔAhzA1zeEa+B·CRzRTBatξz1zrightrightΔAhleft=13600tptp+1|Ibat|dt. …”
Section: Optimal Energy Managementmentioning
confidence: 99%
“…Conversely, for a dynamic process, EH2italicxcoverOCV is assumed to be not constant for the active surface area change under OCV conditions. In previous studies, 0.25emEH2italicxcoverOCV is expressed as Equation , as follows: EH2normalxcoverOCV=Vact=RTαFln()iH2crossi0=RTαFln()IH2italiccross/ECSAi0=RTαFln()IH2crossi0×ECSA where I H2 cross is the absolute crossover current, ECSA denotes the electrochemically active surface areas of a platinum catalyst, and i 0 denotes the exchange current density. When the operating condition is stable, i 0 , I H2 cross , and ECSA are considered as constants.…”
Section: Physical and Mathematical Modelsmentioning
confidence: 99%
“…Conversely, for a dynamic process, E OCV H2−xcover is assumed to be not constant for the active surface area change under OCV conditions. In previous studies, 29,30 E OCV H2−xcover is expressed as Equation 2, as follows:…”
Section: Semiempirical Ocv Modelmentioning
confidence: 99%
“…J C consists of three parts: the capital costs of BT packs, SC packs, and DC/DC converters Cost cap in €/year; the operating cost of electricity Cost ope in €/day; and the replacement cost Cost rep of the BT packs in €/year, and is illustrated in Equation (23). According to the continuous operations of the LHD, we assume that it works 24 h a day and 360 days a year.…”
Section: Life Cycle Cost Model Of Hybrid Essmentioning
confidence: 99%