Multi‐pronged degradation analysis of a photovoltaic power plant after 9.5 years of operation under hot desert climatic conditions

Abstract: Long‐term reliability assessment of photovoltaic (PV) modules is key to ensuring the economic viability of PV systems. This paper presents a multi‐pronged performance degradation analysis of a 62.1 kWp solar PV power plant after 9.5 years of operation. For this purpose, various diagnosis techniques, namely, visual inspection, infrared thermography (IR), ultraviolet fluorescence (UVFL) and current‐voltage (I‐V) characterization, have been performed to evaluate the performance and degradation of the solar PV pow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 69 publications
0
2
0
Order By: Relevance
“…Furthermore, junction boxes can degrade at a faster rate when exposed to large variations in ambient temperature during the year. Daher et al [154] evaluated the reliability of a 9-year PV system (270 modules) installed off-grid that was expected to produce 62 kW in Ali Adde town, Djibouti. The PV system was exposed to the town's high temperatures with dramatic variation from winter (average temperature is 26.7 • C) to summer with an average of 38 • C. Out of 270 modules, 39% were diagnosed with adhesive junction box failure.…”
Section: Junction Box and Bypass Diodesmentioning
confidence: 99%
“…Furthermore, junction boxes can degrade at a faster rate when exposed to large variations in ambient temperature during the year. Daher et al [154] evaluated the reliability of a 9-year PV system (270 modules) installed off-grid that was expected to produce 62 kW in Ali Adde town, Djibouti. The PV system was exposed to the town's high temperatures with dramatic variation from winter (average temperature is 26.7 • C) to summer with an average of 38 • C. Out of 270 modules, 39% were diagnosed with adhesive junction box failure.…”
Section: Junction Box and Bypass Diodesmentioning
confidence: 99%
“…For PVUSA under PTC conditions: 0.057 ± 0.68%/year for DC power and 0.085 ± 0.68%/year for AC power. Also Daher et al (Daher et al 2023)release a study at 2023 given an information about degradation rates of different area for different module technologies. According to this study, the degradation rates are in range between 0.03 % /year (Singapore, c-Si) and 6.5 %/year (Ghana, m-Si and p-Si).…”
Section: Introductionmentioning
confidence: 99%