2020
DOI: 10.1016/j.jmr.2020.106798
|View full text |Cite
|
Sign up to set email alerts
|

Multi-site benchmarking of clinical 13C RF coils at 3T

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
29
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 10 publications
(31 citation statements)
references
References 36 publications
2
29
0
Order By: Relevance
“…The steps for QC [46], including sterilizing the polarizer components and verifying the sample pH, temperature, volume, concentration, and polarization, have been optimized to decrease the time to injection from 88 (74 114) (mean (min max)) [43] to 58 (49 83) s [46] in patients with glioma. Several 13 C RF multichannel coils have been developed to obtain 13 C signals with distinct advantages [47,48]. The choice of use could depend on the regions of interest, head size, and the acquisition methods (e.g., parallel imaging).…”
Section: Considerations In Translating Dynamic Hyperpolarized 13 C Metabolic Imaging To Clinical Brain Studiesmentioning
confidence: 99%
“…The steps for QC [46], including sterilizing the polarizer components and verifying the sample pH, temperature, volume, concentration, and polarization, have been optimized to decrease the time to injection from 88 (74 114) (mean (min max)) [43] to 58 (49 83) s [46] in patients with glioma. Several 13 C RF multichannel coils have been developed to obtain 13 C signals with distinct advantages [47,48]. The choice of use could depend on the regions of interest, head size, and the acquisition methods (e.g., parallel imaging).…”
Section: Considerations In Translating Dynamic Hyperpolarized 13 C Metabolic Imaging To Clinical Brain Studiesmentioning
confidence: 99%
“…In addition to pyruvate, other hyperpolarized 13 C substrates have been investigated from [1,[4][5][6][7][8][9][10][11][12][13] C 2 ]fumarate to [1,[4][5][6][7][8][9][10][11][12][13] C 2 ]malate. Moreover, 13 C-bicarbonate and 13 Ccarbon dioxide have been investigated to measure extracellular pH.…”
Section: Hyperpolarized 13 C Magnetic Resonancementioning
confidence: 99%
“…All elements of the array are separately connected to receiver channels whose outputs are optimally combined with a phase correction, which is dependent on the point in space from which the signal originates. Figure 2 shows an example of SNR images obtained with different geometrical coils for the same cylindrical phantom [7]. Volume (birdcage and Helmholtz), phased array (8, 14, and 16 channels), and surface coils provide very different SNR distributions.…”
Section: Coil Classification: Surface Volume and Phased-array Coilsmentioning
confidence: 99%
See 2 more Smart Citations