2008 IEEE Nuclear Science Symposium Conference Record 2008
DOI: 10.1109/nssmic.2008.4774226
|View full text |Cite
|
Sign up to set email alerts
|

Multi-slice SPECT attenuation and scatter correction using Monte Carlo simulated system matrices

Abstract: Specifying the system matrix is one of the most important processes in computed tomography. For SPECT, the imaging physics can be very difficult to model and approximations are made which result in mismatch between the model and the data. In a move toward better modeling the physics, we developed a Monte Carlo method for specifying the system matrix for small animal imaging (but is also applicable for human imaging). A study was performed using the computergenerated MOBY rat phantom. This phantom returns a hig… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2008
2008
2011
2011

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 8 publications
0
4
0
Order By: Relevance
“…In future studies we plan to implement attenuation and scatter correction using the transmission source on the GE Hawkeye SPECT/CT system. We have performed simulations that showed improvement in quantitation using scatter and attenuation correction [ 35 ]. In a rat it improves quantitation by 10–15%.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In future studies we plan to implement attenuation and scatter correction using the transmission source on the GE Hawkeye SPECT/CT system. We have performed simulations that showed improvement in quantitation using scatter and attenuation correction [ 35 ]. In a rat it improves quantitation by 10–15%.…”
Section: Discussionmentioning
confidence: 99%
“…Collimator response was modeled via ray tracing and excluded the effects of collimator penetration. The system model also excluded the effects of attenuation and scatter; however, we are currently studying these effects via Monte Carlo simulation in a separate investigation [ 34 , 35 ].…”
Section: Methodsmentioning
confidence: 99%
“…System matrix approach. Sauve et al 43 presented an example in micro-ECT with a very long calculation of the system matrix, which is the discrete version of expression (3). At present, it does not seem practical in diagnostic CBCT.…”
Section: Iiib1 Point-scatter-kernel Modelmentioning
confidence: 99%
“…Collimator response was modeled via ray tracing and excluded the effects of collimator penetration. The system model also excluded the effects of attenuation and scatter; however, we are currently studying these effects via Monte Carlo simulation in a separate investigation [6], [7].…”
Section: A Pinhole Spect Data Acquisition and System Modelingmentioning
confidence: 99%