2013
DOI: 10.1016/j.talanta.2012.12.032
|View full text |Cite
|
Sign up to set email alerts
|

Multi-walled carbon nanotube-impregnated agarose film microextraction of polycyclic aromatic hydrocarbons in green tea beverage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
4
3

Relationship

2
5

Authors

Journals

citations
Cited by 54 publications
(25 citation statements)
references
References 34 publications
0
24
0
1
Order By: Relevance
“…300) and of the use of GC–MS for determination. These LODs are lower than those of other methods for determining PAHs in wine (0.1–2 ng L −1 ), fruit‐based soft drinks (0.3–15 ng L −1 ), tea (0.1–50 ng L −1 ) or beer (1.2–3.7 µg L −1 ) . The main advantages of the proposed method include the low volumes of organic solvents it requires thanks to its using a semi‐automated SPE system, which also lowers the risk of contamination from the environment or the analyst.…”
Section: Discussionmentioning
confidence: 67%
See 1 more Smart Citation
“…300) and of the use of GC–MS for determination. These LODs are lower than those of other methods for determining PAHs in wine (0.1–2 ng L −1 ), fruit‐based soft drinks (0.3–15 ng L −1 ), tea (0.1–50 ng L −1 ) or beer (1.2–3.7 µg L −1 ) . The main advantages of the proposed method include the low volumes of organic solvents it requires thanks to its using a semi‐automated SPE system, which also lowers the risk of contamination from the environment or the analyst.…”
Section: Discussionmentioning
confidence: 67%
“…However, some PAHs are not fluorescent and have to be determined with an alternative technique . Thus, PAHs in green tea beverages were determined by HPLC with UV detection following extraction of the analytes by SPME with multi‐walled carbon‐impregnated agarose as sorbent, the resulting sensitivity being comparable to that obtained with HPLC–FLD: 0.1–50 ng L −1 . Gas chromatography with flame ionization detection was also used to determine PAHs in tea .…”
Section: Introductionmentioning
confidence: 99%
“…The amount of analytes extracted increased as the sample volume increased and reached optimum at 15 mL and the extraction efficiency did not increase significantly with further increase in sample volume. This was due to the C 18 film was saturated with the PAHs and further increase in sample volume would not result in the increment of the peak areas [12]. Therefore, 15 mL sample solution was applied for next parameter study.…”
Section: Sample Volumementioning
confidence: 99%
“…Native ligand with electron donor groups (-NH 2 ) on chitosan made it a highly potential dispersion agent for MWCNTs and prevented deactivation of sorbent by agglomeration [63,88].The performance of synthesized composite film was evaluated in -SPE for selected nonsteroidal antiinflammatory drugs and tricyclic antidepressant drugs. Four stacked pieces (5.0 × 5.0 mm 2 ) pierced by a syringe needle were required for each extraction.…”
Section: Agarose/chitosan Reinforced and Blended Mwcnt Microextractionmentioning
confidence: 99%