2008
DOI: 10.1016/j.snb.2007.10.040
|View full text |Cite
|
Sign up to set email alerts
|

Multi-walled carbon nanotubes with poly(methylene blue) composite film for the enhancement and separation of electroanalytical responses of catecholamine and ascorbic acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
66
0
3

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 137 publications
(75 citation statements)
references
References 60 publications
6
66
0
3
Order By: Relevance
“…1, top) shows that the integrity of the Teflon-metal seal was not compromised significantly by the cutting procedure used to form the bare disc from the wire. Interesting aspects of the surface structure of PPD formed from the different isomers of phenylenediamine [27][28][29][30] and other electro-deposited polymers [31][32][33] have been revealed in the past by scanning electron microscopy. Crater-like features described previously for PPD formed on metal cylinders from the ortho monomer [27,30] were also evident at higher magnifications for PPD electro-deposited onto the Pt D electrode ( Fig.…”
Section: Scanning Electron Microscopymentioning
confidence: 99%
“…1, top) shows that the integrity of the Teflon-metal seal was not compromised significantly by the cutting procedure used to form the bare disc from the wire. Interesting aspects of the surface structure of PPD formed from the different isomers of phenylenediamine [27][28][29][30] and other electro-deposited polymers [31][32][33] have been revealed in the past by scanning electron microscopy. Crater-like features described previously for PPD formed on metal cylinders from the ortho monomer [27,30] were also evident at higher magnifications for PPD electro-deposited onto the Pt D electrode ( Fig.…”
Section: Scanning Electron Microscopymentioning
confidence: 99%
“…The Γ value was calculated from the charge (Q) associated with the electropolymerization process according to (Marinho et al 2012, Yogeswaran andChen 2008):…”
Section: Radical Scavenging Capacitymentioning
confidence: 99%
“…EP and NEP can be detected simultaneously by displaying two well-distinguished anodic peaks with a potential difference of 0.240 V. A CNT paste electrode modified with 2,2′-[1,2-ethanediylbis(nitriloethylidyne)]-bishydroquinone can detect EP in the presence of UA and folic acid (Beitollahi et al, 2008a). MWCNT modified GCE can also be functionalized with poly(methylene blue) (PMB) for detection of EP (Yogeswaran and Chen, 2008). The sensitivity and performance of the sensor are improved by the presence of PMB in the composite film.…”
Section: Neurotransmitters/neurochemicalsmentioning
confidence: 99%