2010
DOI: 10.1002/elps.201000071
|View full text |Cite
|
Sign up to set email alerts
|

Multi‐wavelength light emitting diode array as an excitation source for light emitting diode‐induced fluorescence detection in capillary electrophoresis

Abstract: A multi-wavelength LED array was used as an excitation source for in-column fiber-optic LED-induced fluorescence for CE. The light source consisted of a multi-wavelength LED array consisting of three different LEDs (430, 450 and 480 nm), a focusing lens and a gradient index lens group. The LED beam was collimated and reshaped with the gradient index lens group for coupling the LED light source into a single-mode optical fiber. In addition, the luminance and stability of the LED light source was improved by pow… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(9 citation statements)
references
References 24 publications
0
9
0
Order By: Relevance
“…capillary. To our knowledge, except in this work, LODs of most LED-FDs reported so far were at the nano molar level [11][12][13]. The value next to the lowest was 0.29 nM which was reported by Dan Xiao's group [10].…”
Section: Introductionmentioning
confidence: 39%
See 1 more Smart Citation
“…capillary. To our knowledge, except in this work, LODs of most LED-FDs reported so far were at the nano molar level [11][12][13]. The value next to the lowest was 0.29 nM which was reported by Dan Xiao's group [10].…”
Section: Introductionmentioning
confidence: 39%
“…The LOD was evaluated by FIA with a capillary flow cell of 250 mm i.d. The LOD value of 0.75 nM was already among the lowest in literature [11][12][13].…”
Section: Introductionmentioning
confidence: 84%
“…Because there had never been a standard evaluation conditions for LED-FD, the sensitivity was roughly estimated by us. For CE methods, because of the zone concentration effect, the SNR was generally enhanced by several times when the sample was prepared in a buffer much diluter than the running buffer [13,14]. For FIA methods, there is no such concentration effect, but there is a dilution effect instead [11].…”
Section: System Characteristicsmentioning
confidence: 99%
“…Therefore, the light intensity at the detection cell was partly impaired. Recently, LED-FDs that were constructed by using optical lens system and excitation fiber together reached the sensitivity of 10 −10 M [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, our research group has successfully developed in-column optical fiber induced-fluorescence detection system for capillary electrophoresis (CE) [16][17][18][19][20][21][22][23][24][25]. For the in-column optical fiber induced-fluorescence detection system, our previous work demonstrated that an excitation light beam waveguided by an optical fiber to the detection point of the capillary shows relatively lower background light than that obtained from an excitation light beam impinged orthogonally on the capillary exterior wall.…”
Section: Introductionmentioning
confidence: 97%