2019
DOI: 10.18383/j.tom.2018.00030
|View full text |Cite
|
Sign up to set email alerts
|

Multicenter Repeatability Study of a Novel Quantitative Diffusion Kurtosis Imaging Phantom

Abstract: Quantitative kurtosis phantoms are sought by multicenter clinical trials to establish accuracy and precision of quantitative imaging biomarkers on the basis of diffusion kurtosis imaging (DKI) parameters. We designed and evaluated precision, reproducibility, and long-term stability of a novel isotropic (i)DKI phantom fabricated using four families of chemicals based on vesicular and lamellar mesophases of liquid crystal materials. The constructed iDKI phantoms included negative control monoexponential diffusio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
14
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 26 publications
5
14
0
Order By: Relevance
“…Plots of log(ADC) versus inverse temperature in Figure 1c illustrate Arrhenius model fit (Equations ( 2) and ( 3)) used to derive calibration coefficients, C1 and C2, by linear regression (Equation ( 3)). Good alignment of current K40 calibration data to 3-year-old multi-site data 0%, 20%, and 40% [PVP], 25 and other previous K40 PVP studies 15,24 at intermediate temperatures is shown in Figure S4a. This figure also illustrates that for intermediate PVP concentrations not directly calibrated in this work, the linear interpolation can be performed between two calibrated values.…”
Section: Resultssupporting
confidence: 55%
“…Plots of log(ADC) versus inverse temperature in Figure 1c illustrate Arrhenius model fit (Equations ( 2) and ( 3)) used to derive calibration coefficients, C1 and C2, by linear regression (Equation ( 3)). Good alignment of current K40 calibration data to 3-year-old multi-site data 0%, 20%, and 40% [PVP], 25 and other previous K40 PVP studies 15,24 at intermediate temperatures is shown in Figure S4a. This figure also illustrates that for intermediate PVP concentrations not directly calibrated in this work, the linear interpolation can be performed between two calibrated values.…”
Section: Resultssupporting
confidence: 55%
“…Although phantoms based on various easily obtainable substances (including cream and asparagus stems 130 ) provide restricted diffusion, they offer a limited range of diffusion properties. This limitation has been addressed through a variety of synthetic phantoms (e.g., particle suspensions, 130 fibers, 131 and liquid crystal systems 127 ), which provide various diffusion restrictions, but also suffer from a limited range of diffusion properties.…”
Section: Current Status Of Validation and Dissemination Of Diffusion Mrimentioning
confidence: 99%
“…In conclusion, development and validation of quantitative imaging tools for supporting cancer patient trials and ultimately routine clinical adoption have been the focus of the National Institutes of Health Quantitative Imaging Network over the past decade (34,(36)(37)(38). In this present study, we found that ADC histogram percentiles down to 15% have high repeatability and reproducibility, comparable to mean ADC, while low-ADC volumetric measures were substantially less repeatable.…”
Section: Resultsmentioning
confidence: 49%