2014
DOI: 10.1016/j.talanta.2014.04.047
|View full text |Cite
|
Sign up to set email alerts
|

Multicommutated flow analysis system for determination of total protein in cerebrospinal fluid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
6
0
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 18 publications
0
6
0
1
Order By: Relevance
“…Subsequently, and in line with the above, publications in the bio-sensing field began to emerge. Examples include sweat [15][16][17], hemoglobin [18], human serum [19][20][21], proteins [22,23], glucose [24], dissolved organic substances [25], creatinine in physiological fluids [20], urine [26][27][28], liver function screening [29] and saliva [30].…”
Section: Introductionmentioning
confidence: 99%
“…Subsequently, and in line with the above, publications in the bio-sensing field began to emerge. Examples include sweat [15][16][17], hemoglobin [18], human serum [19][20][21], proteins [22,23], glucose [24], dissolved organic substances [25], creatinine in physiological fluids [20], urine [26][27][28], liver function screening [29] and saliva [30].…”
Section: Introductionmentioning
confidence: 99%
“…Koncki et al reported the use of LEDs for both absorption and fluorescence measurement. 25,26 The PEDD has been employed in the analysis of physiological samples, [27][28][29][30][31][32][33][34][35][36][37][38][39][40] drink and food samples [41][42][43][44] and environmental samples. 45 There are also reports of dual analysis employing PEDDs, for example, multicommutated flow (MCFA) system for the determination of activity of acid phosphate and alkaline phosphatase, 46 sequential injection (SI) system for quantitative measurement of sucrose and phosphate, 47 MCFA system for determination of phosphate and calcium, 48 MCFA system for total protein and creatinine analysis 49 and MCFA system for investigation of iron-transferrin and apotransferrin speciation in human serum.…”
Section: Introductionmentioning
confidence: 99%
“…Until now, two and three LED-based fluorimetric detectors have been successfully developed for determination of calcium [ 25 , 26 ] and phosphate [ 14 , 15 ] ions, quinine [ 17 ], vitamin B [ 27 ], and proteins [ 20 ]. Only recently, turbidimetric [ 28 31 ] and nephelometric [ 30 , 31 ] detectors operating according to PEDD principle have been reported. Such detectors have been applied for measurements of sample turbidity [ 28 ] as well as for detection of phosphates in drinks [ 29 ] and total protein level in physiological fluids (urine [ 30 ] and cerebrospinal fluid [ 31 ]).…”
Section: Introductionmentioning
confidence: 99%
“…Only recently, turbidimetric [ 28 31 ] and nephelometric [ 30 , 31 ] detectors operating according to PEDD principle have been reported. Such detectors have been applied for measurements of sample turbidity [ 28 ] as well as for detection of phosphates in drinks [ 29 ] and total protein level in physiological fluids (urine [ 30 ] and cerebrospinal fluid [ 31 ]).…”
Section: Introductionmentioning
confidence: 99%