2019
DOI: 10.1103/physrevaccelbeams.22.053404
|View full text |Cite
|
Sign up to set email alerts
|

Multidiagnostics investigation of the role of the magnetic field profile in a simple mirror trap

Abstract: The impact of the magnetic field profile on the operations of plasma-based Electron Cyclotron Resonance Ion Sources (ECRIS) has been debated and investigated for a long time, and a summary is given by the collection of the so-called "magnetic scaling laws", i.e., some rules-of-thumb providing the optimal configuration of the axial and radial confining magnetic fields. Anyway, the optimal configurations have been found just looking at the output beam currents and charge states. Only recently, more advanced expe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…Let us remind the main modifications done and the outcomes of these experiments. On the SP1-CB, the injection part has been significantly modified by adding a second RF port to inject second RF heating wave within a broad frequency range (8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18); the injection iron plug has been symmetrized; a new gas injection with an outlet close to the ECR plasma has been added; the waveguides orientation has been changed to target the core of the ECR plasma. The majority of the o-Rings have been replaced by metallic gaskets and the plasma chamber is made of aluminum.…”
Section: Spiral1 Charge Breedermentioning
confidence: 99%
See 1 more Smart Citation
“…Let us remind the main modifications done and the outcomes of these experiments. On the SP1-CB, the injection part has been significantly modified by adding a second RF port to inject second RF heating wave within a broad frequency range (8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18); the injection iron plug has been symmetrized; a new gas injection with an outlet close to the ECR plasma has been added; the waveguides orientation has been changed to target the core of the ECR plasma. The majority of the o-Rings have been replaced by metallic gaskets and the plasma chamber is made of aluminum.…”
Section: Spiral1 Charge Breedermentioning
confidence: 99%
“…The objective was to study and find a set of SP1-CB parameters which minimizes the charge breeding time while maximizing the charge breeding efficiency; that set matches the best RIB production environments to maximize the yields on the physicist's target regarding the SP1-CB device [14]. to be at the edge of the plasma stability / instability region and to lead to the production of highly charged ions [15].…”
Section: Spiral1 Charge Breedermentioning
confidence: 99%
“…These studies can be characterised based on whether or not the obtained results provide spatially and/or temporally resolved information, as well as based on the origin of the measured bremsstrahlung (plasma emission, thick target radiation induced by escaping electrons). Techniques resulting to volume integrated and time averaged results have been used most widely to probe the general plasma properties [6][7][8][9][10][11][12][13][14][15][16], but there has been also significant development in the use of spatially [17,18] and temporally [19] resolved methods. However, unambiguous de-convolution of either thick-target (wall) or plasma bremsstrahlung spectra to obtain the electron energy distribution (EED) of the escaping or confined electrons is seemingly impossible despite some notable efforts [13,20,21].…”
Section: Introductionmentioning
confidence: 99%
“…Typical operating frequencies are in the range 4-7 GHz. It has been experimentally demonstrated that, when FPT is operated in simple mirror magnetic configuration, there exists a threshold value of the B min /B ECR ratio beyond which X-ray emission is increased by orders of magnitude independently of the operative frequency [6,7]. Moreover, several experiments have shown that, when B min /B ECR > 0.75, CM instabilities can be revealed [3,8].…”
Section: The Experimental Set-up and Strategymentioning
confidence: 99%