2011
DOI: 10.1002/jps.22331
|View full text |Cite
|
Sign up to set email alerts
|

Multidisciplinary Approach on Characterizing a Mechanochemically Activated Composite of Vinpocetine and Crospovidone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
25
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 22 publications
(33 citation statements)
references
References 25 publications
7
25
1
Order By: Relevance
“…The use of a fiber optic apparatus (HELLMA, Milano, Italy), connected to a spectrophotometer (ZEISS, Germany, wavelength 270.19 nm), permitted the determination of VIN concentration without perturbing the release environment (each release test lasted 120 min). Moreover, this methodology, previously successfully employed for coground systems containing VIN (15), allowed for easily overcoming the problem connected to drug concentration measurements in the presence of a dispersion of solid particles. Indeed, whilst the maximum VIN absorption occurred at 270.19 nm, the maximum citric acid absorption was at 220.49 nm, and the scattering effect due to polymeric particles uniformly occurred at every wavelength.…”
Section: Dissolution Kinetics Tests (Dkt)mentioning
confidence: 98%
See 2 more Smart Citations
“…The use of a fiber optic apparatus (HELLMA, Milano, Italy), connected to a spectrophotometer (ZEISS, Germany, wavelength 270.19 nm), permitted the determination of VIN concentration without perturbing the release environment (each release test lasted 120 min). Moreover, this methodology, previously successfully employed for coground systems containing VIN (15), allowed for easily overcoming the problem connected to drug concentration measurements in the presence of a dispersion of solid particles. Indeed, whilst the maximum VIN absorption occurred at 270.19 nm, the maximum citric acid absorption was at 220.49 nm, and the scattering effect due to polymeric particles uniformly occurred at every wavelength.…”
Section: Dissolution Kinetics Tests (Dkt)mentioning
confidence: 98%
“…The first 5 μl of the filtrates were discarded, while the subsequent was collected. Then, an appropriate amount of the filtrate was diluted with acetonitrile and assayed by a validated high pressure liquid chromatographic (HPLC) with mass spectrometry (MS) detection method (24) already used in our previous work (15).…”
Section: Hplc Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…7 This base-type drug (pKa = 7.1) 8 was chosen as a model drug because it is practically insoluble in water (1.6 mg mL -1 in pH = 7.4 at 37 °C). 9 Vinpocetine melting temperature (T m∞ = 149.6 °C), melting enthalpy (DH m∞ = 94600 J kg -1 ) and DC p (difference in specific heat capacity at constant pressure between the liquid ( ) was evaluated according to the group contribution approach 10,11 implemented by the Breitkreutz software. 12 Determination of the solid vinpocetine -vapor surface tension ( …”
Section: Methodsmentioning
confidence: 99%
“…In these experiments, the solution was kept homogeneous using an impeller (rotational speed 200 rpm) and the determination of HTA concentration was performed using fibreoptic apparatus (HELLMA, Milano, Italy) connected to a spectrophotometer (ZEISS, Germany,). 21 Measurement was 25 performed at 286.9 nm (HTA maximum absorption, supporting information). Each sample was tested in triplicate.…”
Section: Componentsmentioning
confidence: 99%