1999
DOI: 10.1016/s0003-2670(99)00005-7
|View full text |Cite
|
Sign up to set email alerts
|

Multielement instrumental activation analysis based on gamma–gamma coincidence spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0
1

Year Published

2008
2008
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 5 publications
0
7
0
1
Order By: Relevance
“…4 NIST SRM 2556 (Used Auto Catalyst) was thus chosen to validate the accuracy of the developed methodology. SRM 2556 is certified only for Pb and other PGEs, i.e., Pt (697.4 mg kg −1 ), Pd (326 mg kg −1 ), and Rh (51.2 mg kg −1 ), but Vobeckýet al 56 earlier reported an estimate of 19 μg kg −1 Ir by instrumental activation analysis when utilizing a coincidence spectrometer. As Ir may be present in SRM 2556 as a metallic impurity that is resistant to attack by all acids, including aqua regia, sample preparation excludes the use of conventional wet acid digestion techniques for solubilization.…”
Section: Figures Of Meritmentioning
confidence: 99%
See 1 more Smart Citation
“…4 NIST SRM 2556 (Used Auto Catalyst) was thus chosen to validate the accuracy of the developed methodology. SRM 2556 is certified only for Pb and other PGEs, i.e., Pt (697.4 mg kg −1 ), Pd (326 mg kg −1 ), and Rh (51.2 mg kg −1 ), but Vobeckýet al 56 earlier reported an estimate of 19 μg kg −1 Ir by instrumental activation analysis when utilizing a coincidence spectrometer. As Ir may be present in SRM 2556 as a metallic impurity that is resistant to attack by all acids, including aqua regia, sample preparation excludes the use of conventional wet acid digestion techniques for solubilization.…”
Section: Figures Of Meritmentioning
confidence: 99%
“…It should be noted that this type of spectral interference does not occur with FI-PVG because the PVG efficiency for Pt at 1 μg L −1 under conditions optimal for Ir was found to be negligible (≈0.23%). Interestingly, the PVG efficiencies of the other two PGEs present at high concentrations and certified in SRM 2556 were also tested and found to be very low, reaching ≈0.07% for Pd 56 The practical feasibility of determination of dissolved Ir (as Ir 3+ and Ir 4+ ) at extremely low concentrations was also examined by a direct analysis of five water samples of different matrix complexity. No dilution of the water samples was required except for the addition of concentrated HCOOH and solutions of sensitizers (final dilution factor of only 1.19).…”
Section: Figures Of Meritmentioning
confidence: 99%
“…Despite subsequent early work [4, 5], only occasional applications have been reported in analytical chemistry [69]. In contrast coincidence counting is well established in nuclear structure studies where it is routinely used by nuclear spectroscopists to elucidate complex decay schemes.…”
Section: Introductionmentioning
confidence: 99%
“…While the technique is commonly used in nuclear structure analysis to construct radioactive decay schemes, its application in neutron activation analysis (NAA) has been limited. Previous research has explored the technique's usefulness in NAA, and experiments confirm that it has advantages to offer over singles counting [1]–[3]. Previous research also suggests reasons for its lack of popularity [4].…”
Section: Introductionmentioning
confidence: 99%