2011 16th International Solid-State Sensors, Actuators and Microsystems Conference 2011
DOI: 10.1109/transducers.2011.5969344
|View full text |Cite
|
Sign up to set email alerts
|

Multilayer phased microcoil array for magnetic resonance imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…It should be noted that the results seen with this concentrations might not be optimal for other cell types or systems, additional measurements being necessary to determine optimal MnCl 2 concentration in this case. To alleviate the time restrictions imposed by the current experimental design, phased array planar microcoils integrated on a multisample platform were developed (57) allowing for future parallel investigations of MnCl 2 uptake dynamics at multiple concentrations.…”
Section: Discussionmentioning
confidence: 99%
“…It should be noted that the results seen with this concentrations might not be optimal for other cell types or systems, additional measurements being necessary to determine optimal MnCl 2 concentration in this case. To alleviate the time restrictions imposed by the current experimental design, phased array planar microcoils integrated on a multisample platform were developed (57) allowing for future parallel investigations of MnCl 2 uptake dynamics at multiple concentrations.…”
Section: Discussionmentioning
confidence: 99%
“…The magnetic field generation requires an electrical current flow, which has a dramatic impact on the power dissipation and thermal budget characteristics of the manufactured components. Self-heating of the windings poses a reliability issue as the metal tends to expand while embedded in the insulating matrix, e.g., SU-8 [122][123][124] or Parylene [125][126][127]. This can potentially force an uncontrolled stress load on the device.…”
Section: Excitation Sourcesmentioning
confidence: 99%
“…In [81,82], an array of seven mutually overlapping microcoils, each of around 2 mm diameter, was produced (Table 2-d). Each microcoil was tuned to 400 MHz and matched to 50 Ω.…”
Section: Unconventional Applications Of Wire Bonding Using Standard Wmentioning
confidence: 99%
“…In principle, the posts around which the wire is wrapped and hence plastically deformed can be used to define other shapes. By lithographically forming SU-8 posts, [81] has formed hexagonal coils, [94] has produced a low self-capacitance basket coil (Table 2-j), and [95] has formed a longitudinal magnetic resonance microgradient coil (Table 2-k). In [96], PMMA is structured via laser to form a yoke around which a record 100 windings are wound (Table 2-i).…”
Section: Unconventional Applications Of Wire Bonding Using Standard Wmentioning
confidence: 99%
See 1 more Smart Citation