2012
DOI: 10.1186/1532-429x-14-s1-p98
|View full text |Cite
|
Sign up to set email alerts
|

Multimodality imaging in transcatheter aortic valve implantation: comparison between cardiovascular magnetic resonance, cardiac computed tomography, transesophageal and transthoracic echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
20
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(20 citation statements)
references
References 0 publications
0
20
0
Order By: Relevance
“…More recently, multislice computed tomography (CT) has emerged as an alternative and perhaps superior technique (4). CT provides a more reliable and detailed anatomical assessment of the aortic valvular complex and yields larger aortic annular diameters than echocardiography (5)(6)(7)(8)(9)(10)(11). Consequently, echocardiographic-based TAVR sizing may be inaccurate and may fail to provide the expected THV oversizing.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…More recently, multislice computed tomography (CT) has emerged as an alternative and perhaps superior technique (4). CT provides a more reliable and detailed anatomical assessment of the aortic valvular complex and yields larger aortic annular diameters than echocardiography (5)(6)(7)(8)(9)(10)(11). Consequently, echocardiographic-based TAVR sizing may be inaccurate and may fail to provide the expected THV oversizing.…”
mentioning
confidence: 99%
“…Consequently, echocardiographic-based TAVR sizing may be inaccurate and may fail to provide the expected THV oversizing. Supporting this hypothesis is the observation that the rates of both PVL and mortality decline with CT-based sizing (5)(6)(7)(8)(9)(10)(11). Although it is axiomatic that the superiority of CT-based sizing is achieved through more accurate adherence to manufacturer THV-oversizing principles, this hypothesis has not been corroborated.…”
mentioning
confidence: 99%
“…CMR provides better anatomical information than echocardiography regarding the aorta and gives systematically larger and probably more accurate estimates for annulus size. The agreement between CMR and TTE on TAVI size selection in one study33 was only 14% (Îș=−0.06) compared with 50% (Îș=0.31) between MDCT and CMR. Paraprosthetic regurgitation was uncommon and was associated with large annulus size on CMR but not on TTE, which calls into question the significance of discrepancies between sizing by CMR and TTE.…”
Section: Non-echocardiographic Imaging Modalitiesmentioning
confidence: 93%
“…21 Transcatheter aortic valve replacement (TAVR): post-procedural evaluation Following TAVR insertion, MDCT can be utilized to assess for accurate device positioning, in the intermediate to long-term follow-up period. 22 When assessing for TAVR positioning, a double oblique axial projection that is orthogonal to the aortic root is required to evaluate the expansion, circularity and apposition of the TAVR prosthesis. Additionally, implantation depth can be evaluated by a long-axis or coronal oblique view, assessing the margins of the prosthesis in relation to the native valve annulus and coronary arteries.…”
Section: Clinical Applications Of Mdct In Structural Heart Interventionsmentioning
confidence: 99%