Multiphase Computed Tomographic Angiography with Bone Subtraction Using 3D Multichannel Convolution Neural Networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 10 publications
0
5
0
Order By: Relevance
“…The CTA images needed to be preprocessed. The coarse-to-fine (C2F) method [ 12 ] was adopted to segment the arteries in CTA images. After the upsampling of the original CTA image I in the coarse segmentation, the obtained coarse segmentation output image is expressed as equation ( 1 ): …”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The CTA images needed to be preprocessed. The coarse-to-fine (C2F) method [ 12 ] was adopted to segment the arteries in CTA images. After the upsampling of the original CTA image I in the coarse segmentation, the obtained coarse segmentation output image is expressed as equation ( 1 ): …”
Section: Methodsmentioning
confidence: 99%
“…Sensitivity (Sen) was utilized to measure the probability that a voxel that was positive in the gold standard was also positive in the segmentation result, and it is calculated using equation (12):…”
Section: Evaluation Indicators Of Cta Image Segmentationmentioning
confidence: 99%
See 1 more Smart Citation
“…Consistency loss. In order to form constraints between the original H-phase (or E-phase) image and its style-transferred image and make the segmentation network learn useful knowledge lost due to style transfer, Consistency loss L CON is set between the corresponding prediction results P A and P A→V , as shown in Equation (7).…”
Section: Loss Functionmentioning
confidence: 99%
“…Clinically, multiphase computer tomography angiography (CTA) images are obtained by scanning at different times of peak venous flow. Due to the complementary vessel information on these images presenting a comprehensive status of the collateral circulation, they are routinely used for disease diagnosis and patient prognosis prediction [ 7 ]. For example, the diagnosis of portal vein disease often depends on observing the portal vein on the abdominal CTA images of the hepatic artery phase (H-phase), the portal vein phase (P-phase) and the equilibrium phase (E-phase) simultaneously, and intuitively fusing CTA images of different phases, so as to complement vessel information and implement effective treatment [ 8 ].…”
Section: Introductionmentioning
confidence: 99%