2021
DOI: 10.1109/tie.2020.3005096
|View full text |Cite
|
Sign up to set email alerts
|

Multiphase PFC Rectifier and Modulation Strategies for Domestic Induction Heating Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 26 publications
0
8
0
Order By: Relevance
“…To increase the efficiency of the system topology and to reduce the number of components, single-stage AC-AC resonant converters have been proposed [24,26,[67][68][69][70][71][72][73][74][75][76]. Figure 7 shows the general block diagram of the single-stage power conversion topology.…”
Section: Direct Ac-ac Converter Topologiesmentioning
confidence: 99%
“…To increase the efficiency of the system topology and to reduce the number of components, single-stage AC-AC resonant converters have been proposed [24,26,[67][68][69][70][71][72][73][74][75][76]. Figure 7 shows the general block diagram of the single-stage power conversion topology.…”
Section: Direct Ac-ac Converter Topologiesmentioning
confidence: 99%
“…Conventional ac-dc converters are intended to act as rectifiers with a unity power factor. For example, boosttype converters that follow the passive diode bridge rectifiers are used for the power factor correction for lighting loads [66]- [72], home appliances [73]- [74], and other devices [75]- [76]. However, additional features are necessary in dc microgrids, as was discussed in Section II.…”
Section: Isolated Ac-dc Power Conversion: Overview Of Topologies and ...mentioning
confidence: 99%
“…The most interesting topologies for domestic IH are the boost topologies, because they get a higher voltage in comparison with buck topologies, decreasing the current in the IH inverters and coils, improving consequently the efficiency. In this way, [9] proposes a multi‐phase stage. This front‐end PFC merges the mains phases in the same bus voltage, v b , getting a good PF and a decreased THD of the mains currents.…”
Section: Pfc and Matrix Convertermentioning
confidence: 99%
“…The current limitations of domestic IH, in general, and the flexible surface technology, in particular, can be overcome by using an additional power conversion stage (Figure 1) to sepa-rate the IH inverters from the mains, as it has been previous discussed in [8][9][10]. This solution enables obtaining a good EMC performance [11][12][13] and decreasing the design constraints of IH inverters [14,15].…”
Section: Introductionmentioning
confidence: 99%