1983
DOI: 10.2214/ajr.141.6.1203
|View full text |Cite
|
Sign up to set email alerts
|

Multiple NMR T2 relaxation values in human liver tissue

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
8
0
2

Year Published

1986
1986
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 40 publications
(12 citation statements)
references
References 16 publications
2
8
0
2
Order By: Relevance
“…Similar to previous NMR reports , our study demonstrates two components of the T 2 signal decay of liver tissue. However, in comparison with previous NMR reports, in which both the short and long T 2 components were typically found to be shorter than 110 ms , the long T 2 component in this study was found to approximate 400 ms. Differences in the reports may stem from differences in technique (NMR versus MRI, which introduces effects related to slice selection, etc.)…”
Section: Discussionsupporting
confidence: 91%
See 2 more Smart Citations
“…Similar to previous NMR reports , our study demonstrates two components of the T 2 signal decay of liver tissue. However, in comparison with previous NMR reports, in which both the short and long T 2 components were typically found to be shorter than 110 ms , the long T 2 component in this study was found to approximate 400 ms. Differences in the reports may stem from differences in technique (NMR versus MRI, which introduces effects related to slice selection, etc.)…”
Section: Discussionsupporting
confidence: 91%
“…In comparing the results presented herein with previous work, several variables must be considered which may influence the T 2 spectra, including differences in the features of the raw data acquisition, such as the signal‐to‐noise ratio, data acquisition window width and sampling density, as well as features of the subsequent MET 2 processing, including the choice of data processing methodology as well as the analysis routine (region of interest versus pixel by pixel), among others . Similar to previous NMR reports , our study demonstrates two components of the T 2 signal decay of liver tissue. However, in comparison with previous NMR reports, in which both the short and long T 2 components were typically found to be shorter than 110 ms , the long T 2 component in this study was found to approximate 400 ms.…”
Section: Discussionsupporting
confidence: 79%
See 1 more Smart Citation
“…Tissue iron is detected indirectly by the effects on relaxation times by the interaction of ferritin and hemosiderin iron with hydrogen nuclei in normal cardiac tissue. The presence of iron in human body results in marked alteration in tissue relaxation times (15,28,29).…”
Section: Mri Principlesmentioning
confidence: 99%
“…28 Here we consider the spin-spin time constant, T2. Due to local differences in proton environment, relaxation processes may be multi-exponential, 29 and time, temperature and fixation all alter relaxation ex vivo. 30,31 Measurements are also affected by diffusion 32 and field strength.…”
Section: Introductionmentioning
confidence: 99%