Multiplexed Ion Mobility Spectrometry-Orthogonal Time-of-Flight Mass Spectrometry

Abstract: Ion mobility spectrometry (IMS) coupled to orthogonal time-of-flight mass spectrometry (oTOF) has shown significant promise for the characterization of complex biological mixtures. The enormous complexity of biological samples (e.g. from proteomics) and the need for both biological and technical analysis replicates imposes major challenges for multidimensional separation platforms in regard to both sensitivity and sample throughput. A major attraction of the IMS-TOF MS platform is separation speeds exceeding t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
74
1

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 69 publications
(75 citation statements)
references
References 41 publications
(67 reference statements)
0
74
1
Order By: Relevance
“…Thus, for a continuous ion source, the introduction of a short pulse of ions upon initiation of experiments often limits duty cycles. Researchers have used a number of approaches (including utilizing multiple injections, as well as Fourier and Hadamard transform approaches) to improve duty cycles (100)(101)(102). Alternatively, at low pressures, it is possible to store ions for extended times to accumulate continuous signals into concentrated packets.…”
Section: Peak Shape and Resolving Power Considerationsmentioning
confidence: 99%
“…Thus, for a continuous ion source, the introduction of a short pulse of ions upon initiation of experiments often limits duty cycles. Researchers have used a number of approaches (including utilizing multiple injections, as well as Fourier and Hadamard transform approaches) to improve duty cycles (100)(101)(102). Alternatively, at low pressures, it is possible to store ions for extended times to accumulate continuous signals into concentrated packets.…”
Section: Peak Shape and Resolving Power Considerationsmentioning
confidence: 99%
“…To address this constraint, a multiplexing approach based on the Hadamard transform was developed so that discreet packets of ions could co-exist in the drift cell as long as they did not overlap due to diffusional broadening ( Fig. 1B and 1C) (15). This approach substantially circumvents space charge limitations, allows much higher IMS duty cycle, significantly increases measurement sensitivity, and deconvolution of its pseudorandom sequence has been shown to greatly reduce the noise in the spectra allowing a much higher signal to noise ratio for the resulting ions (16).…”
Section: Ims-ms Developments and Improvements To Increasementioning
confidence: 99%
“…In theory, ESI-IMMS spectra can be obtained in a few milliseconds with high resolution, providing a rapid multidimensional separation of the sample components (Belov et al 2007;Merenbloom et al 2006;Steiner et al 2001). The separation potential of ESI-IMMS, however, has not been characterized as has those of chromatography or mass spectrometry.…”
Section: Introductionmentioning
confidence: 99%