2013
DOI: 10.1021/ac403171u
|View full text |Cite
|
Sign up to set email alerts
|

Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry: A High-Throughput Platform for Metabolomics with High Data Fidelity

Abstract: A major constraint in large-scale mass spectrometry (MS)-based metabolomic initiatives is the low sample throughput associated with chromatographic or electrophoretic separations. Herein, we introduce multisegment injection-capillary electrophoresis-mass spectrometry (MSI-CE-MS) as a multiplexed separation platform for metabolomics that increases sample throughput up to one order of magnitude while improving overall data fidelity. We demonstrate that serial injection of seven or more discrete sample segments c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
127
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 103 publications
(128 citation statements)
references
References 36 publications
0
127
0
Order By: Relevance
“…Nevertheless, a major drawback of these conventional separation methods is the low sample throughput, so other complementary approaches are emerging in order to reduce the time of analysis. Kuehnbaum et al [11] described a multiplexed separation platform for plasma metabolomics based on multisegment injection-capillary electrophoresis-mass spectrometry, which increases sample throughput up to one order of magnitude while improving overall data fidelity. Alternatively, the use of ambient ionization techniques has extended the utility of mass spectrometry to direct analysis of complex solid materials or liquid aerosols without the need for sample pretreatment or extraction [12].…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, a major drawback of these conventional separation methods is the low sample throughput, so other complementary approaches are emerging in order to reduce the time of analysis. Kuehnbaum et al [11] described a multiplexed separation platform for plasma metabolomics based on multisegment injection-capillary electrophoresis-mass spectrometry, which increases sample throughput up to one order of magnitude while improving overall data fidelity. Alternatively, the use of ambient ionization techniques has extended the utility of mass spectrometry to direct analysis of complex solid materials or liquid aerosols without the need for sample pretreatment or extraction [12].…”
Section: Introductionmentioning
confidence: 99%
“…A cohort of overweight/obese women were recruited to participate in a 6-week HIIT intervention, and standardized OGTTs were performed for each subject prior to and after exercise training using a repeated measures/cross-over study design. Multi-segment injection-capillary electrophoresis-mass spectrometry (MSI-CE-MS) was used as a novel high-throughput platform in metabolomics22 for classification of plasma metabolites modulated by glucose loading and/or training status. Multiplexed separations based on MSI-CE-MS also provide an accelerated workflow for biomarker discovery since time-dependent changes in plasma metabolism are captured within a single run for an individual subject ( i.e.…”
mentioning
confidence: 99%
“…A solution to this issue of a long dead time between injection and the appearance of peaks in CZE was introduced by Larmann and Jorgenson in 1993 as part of an RPLC-CZE interface (22), and redeveloped in a modified form by Kuehnbaum and colleagues in 2013 for analysis of metabolites (23). In these methods, a series of injections is performed at time periods greater than the separation window but less than the total analysis time.…”
Section: Introductionmentioning
confidence: 99%
“…In these methods, a series of injections is performed at time periods greater than the separation window but less than the total analysis time. This technology has been applied this method to the analysis of metabolites in human plasma (2426), and demonstrated efficient generation of calibration curves, standard addition analysis, and serial dilutions (23). …”
Section: Introductionmentioning
confidence: 99%