Multivariable integral linear quadratic Gaussian robust control of islanded microgrid to mitigate voltage oscillation for improving transient response

Abstract: A novel robust integral linear quadratic Gaussian (ILQG) controller is presented in this paper to control the voltage of islanded microgrid and improves its transient response. Microgrid is a small grid that consists of number of distributed generator units, power-electronic components with inductor-capacitor (LC) filters and loads. The loads are parametrically uncertain and unknown that produces the voltage or power oscillation. The ILQG controller is capable to compensate for the voltage oscillation and exhi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 28 publications
0
14
0
Order By: Relevance
“…Here, the inverter is represented by power converter block where terminal P and Q are connected to the grid side through filter inductors. The leakage current is thus the function of grid voltage(V G ), parasitic capacitance (C P ), V PN , V QN and filter inductances and capacitance, where, V PN is the voltage between the points P and N, and V QN is the voltage between the points Q and N. Thus, The differential mode (DM) voltage, V PQ can be represented as [43], (11) and the CM voltage is,…”
Section: Leakage Current Problem Analysis Of Transformerless Invementioning
confidence: 99%
See 1 more Smart Citation
“…Here, the inverter is represented by power converter block where terminal P and Q are connected to the grid side through filter inductors. The leakage current is thus the function of grid voltage(V G ), parasitic capacitance (C P ), V PN , V QN and filter inductances and capacitance, where, V PN is the voltage between the points P and N, and V QN is the voltage between the points Q and N. Thus, The differential mode (DM) voltage, V PQ can be represented as [43], (11) and the CM voltage is,…”
Section: Leakage Current Problem Analysis Of Transformerless Invementioning
confidence: 99%
“…During the large disturbance, the MG is disconnected from the main grid through PCC and allow to operate independently. The VSI is the key element that converts the DC power which is stored in the energy storage system to AC whose operation is quite challenging [10], [11]. These inverters are built with or without transformer.…”
Section: Introductionmentioning
confidence: 99%
“…Linear quadratic regulator (LQR), designed by linearization technique, is an approach to achieve accurate operation of the microgrid system [30], [31]. The LQR is developed using a mean value theorem.…”
Section: B Literature Reviewmentioning
confidence: 99%
“…The frequency counter gives the accurate line frequency value of 50.41 Hz as shown in Fig. 12 and the phase difference between voltage and current is 53.716 • obtained from (4). After collecting the instrumental data and finishing some calculations, the system obtains some parameters, as shown in Table 2.…”
Section: Ac Power Measured By the Measuring Devicementioning
confidence: 99%
“…The power factor directly relates to the system efficiency and performance. A large amount of load current results in lower voltage regulation of the system and provides a large joule loss in the power lines [4,5]. The lower voltage level generates heat in the motor windings that reduces the lifetime, reliability and performance of the machine [6,7].…”
Section: Introductionmentioning
confidence: 99%