2007
DOI: 10.1016/j.sab.2007.02.013
|View full text |Cite
|
Sign up to set email alerts
|

Multivariate correction in laser-enhanced ionization with laser sampling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…To reduce the strong matrix effects caused by the microstructure of ferrites, we decided to use a multivariate correlation approach applied to correct matrix variations of aluminium aviation alloys. 28 The approach utilized a 3D correlation plot, where the Z axis corresponded to analytical LEI signal, the Y axis corresponded to the reference acoustic signal and the X axis corresponded to the reference emission signal. Considerable multicollinearity between reference signals (see Table 3) resulted in the points in 3D space being scattered near a curve instead of a plane.…”
Section: Multivariate Correctionmentioning
confidence: 99%
See 1 more Smart Citation
“…To reduce the strong matrix effects caused by the microstructure of ferrites, we decided to use a multivariate correlation approach applied to correct matrix variations of aluminium aviation alloys. 28 The approach utilized a 3D correlation plot, where the Z axis corresponded to analytical LEI signal, the Y axis corresponded to the reference acoustic signal and the X axis corresponded to the reference emission signal. Considerable multicollinearity between reference signals (see Table 3) resulted in the points in 3D space being scattered near a curve instead of a plane.…”
Section: Multivariate Correctionmentioning
confidence: 99%
“…For this purpose, the optimization of experimental set-up and detection conditions is required to operate with several reference signals (optoacoustic, emission from matrix and ion probe current) and to realize the multivariate correction for LA-LEI thoroughly described for aluminium alloys analysis. 28 Fig. 1 Experimental set-up: 1ablation laser, 2laser energy meter, 3microscope, 4pump laser, 5, 6dye lasers, 7burner head, 8cathode, 9monochromator with PMT, 10microphone, 11delay generator, 12computer, Aamplifiers, BSbeam splitters, HVhigh voltage supply modules, Mmirrors.…”
Section: Introductionmentioning
confidence: 99%
“…Popov et al 310 performed a multivariate correction method to address the matrix problems associated with LEI. The following were used as reference signals and were measured simultaneously: opto-acoustic, atomic emission and non-selective ionization signals.…”
Section: Laser Enhanced Ionisation (Lei)mentioning
confidence: 99%
“…In the past, normalization approaches have been generally applied to minimize uncertainty and improve the stability of spectral signal [13]. The acoustic wave from ablation has been virtually used as a reference signal for pulse-to-pulse correction [14], Mie-scattering has been presented as a reference signal to correct the variations in amount of particulates [15]. Also, spectral fluctuations have been corrected by normalizing of the reference spectral signal (total plasma emission within a spectral window, emission background, internal standard or reference line) [13].…”
Section: Introductionmentioning
confidence: 99%