2004
DOI: 10.1016/s0039-9140(04)00028-1
|View full text |Cite
|
Sign up to set email alerts
|

Multivariate monitoring of soybean oil ethanolysis by FTIR

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
56
0
8

Year Published

2007
2007
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(64 citation statements)
references
References 0 publications
0
56
0
8
Order By: Relevance
“…56 Métodos espectroscópicos vibracionais, aliados à análise multivariada, têm sido estudados com o objetivo de estabelecer modelos de calibração. Estes apresentam vantagens de não serem métodos destrutivos, não necessitarem de reagentes e tratamento da amostra, de possuírem aceitável precisão e exatidão, serem rápidos e pouco laboriosos, 57 além de poderem ser aplicados ao monitoramento in situ da reação de trasesterificação.…”
Section: Métodos Analíticos Multivariados Na Análise De Biodieselunclassified
“…56 Métodos espectroscópicos vibracionais, aliados à análise multivariada, têm sido estudados com o objetivo de estabelecer modelos de calibração. Estes apresentam vantagens de não serem métodos destrutivos, não necessitarem de reagentes e tratamento da amostra, de possuírem aceitável precisão e exatidão, serem rápidos e pouco laboriosos, 57 além de poderem ser aplicados ao monitoramento in situ da reação de trasesterificação.…”
Section: Métodos Analíticos Multivariados Na Análise De Biodieselunclassified
“…In previous studies, different analytical methods such as gas chromatography [17,18], high performance liquid chromatography [19], Fourier transform infrared spectroscopy [20,21] have been developed to off-line monitor the composition of reaction mixtures (FFA, ethyl esters, MG, DG, TG, glycerol) obtained during or after transesterification of vegetable oils with ethanol. Nevertheless, these techniques are long to handle and expensive.…”
Section: Introductionmentioning
confidence: 99%
“…22 In many of these cases, the use of multivariate calibration methods is an alternative to reduce the interferent effect, improving the selectivity of these instrumental methods. [23][24][25][26] This method can be useful for simultaneous determination of dopamine and ascorbic acid when only the modification of the electrode surface is not sufficient to separate significantly the oxidation peaks of both substrates. To our knowledge multivariate calibration methodology has not been combined with voltammetry for the separation of dopamine and ascorbic acid.…”
Section: Introductionmentioning
confidence: 99%