2010
DOI: 10.1016/j.echo.2010.06.028
|View full text |Cite
|
Sign up to set email alerts
|

Myocardial Tissue Doppler Velocity Imaging in Children: Comparative Study between Two Ultrasound Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

4
19
0

Year Published

2011
2011
2021
2021

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 29 publications
(23 citation statements)
references
References 22 publications
4
19
0
Order By: Relevance
“…TDI results from fetus to neonate were similar whether the same or different equipment were used. Recently, Koopman et al [29] reported the inter-machine comparability of TDI parameters in children. They concluded that the agreement between Phillips-derived and GE-derived TDI was reasonable; however, we recommend the same ultrasound system for measurement of serial changes.…”
Section: Discussionmentioning
confidence: 99%
“…TDI results from fetus to neonate were similar whether the same or different equipment were used. Recently, Koopman et al [29] reported the inter-machine comparability of TDI parameters in children. They concluded that the agreement between Phillips-derived and GE-derived TDI was reasonable; however, we recommend the same ultrasound system for measurement of serial changes.…”
Section: Discussionmentioning
confidence: 99%
“…Averaging measurements over multiple beats slightly reduced variability, but it is still unclear if this extra step results in clinically significant gains. In our laboratory we validated the inter-and intra-observer variability of the different functional parameters including TDI and STE measurements [7][8][9]. Longitudinal and circumferential end systolic strain measurements have low inter-and intra-observer variability; however, radial strain and all measures of strain rate are more variable [7].…”
Section: • Validation Of Measurementsmentioning
confidence: 99%
“…Based on our research work on intermachine variability of tissue Doppler and strain measurements [7][8][9], all functional imaging at our laboratory is performed on a machine from a single vendor (Vivid 7 or E9, GE Healthcare, WI, USA). This reduces variability and makes serial comparisons during follow-up easier.…”
Section: Equipmentmentioning
confidence: 99%
“…In contrast, speckle tracking is more of a ‘black box’ and the user may not be aware of the precise impact of factors such as computational differences (natural versus Lagrangian strain) or the spatial and temporal resolution of the technique1. Recent work in children has demonstrated the impact of the use of different proprietary software on restudy of the same patient with respect to deformation imaging12, 13. This limits the ease of comparison of results between and within centers.…”
mentioning
confidence: 99%