2008
DOI: 10.1016/j.jnucmat.2008.02.073
|View full text |Cite
|
Sign up to set email alerts
|

Nano-indentation measurement of oxide layers formed in LBE on F/M steels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
20
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 33 publications
(25 citation statements)
references
References 13 publications
5
20
0
Order By: Relevance
“…The inner layer is more homogeneous, but it also varies in its thickness, particularly with regard to its penetration into the substrate steel. While such variation in thickness is probably due in part to the level of polishing of the surface (to 600 grit) performed prior to the pre-oxidation, it has also been observed by other researchers [11,15]. Fig.…”
Section: Conductivity (S/cm) Hsupporting
confidence: 55%
“…The inner layer is more homogeneous, but it also varies in its thickness, particularly with regard to its penetration into the substrate steel. While such variation in thickness is probably due in part to the level of polishing of the surface (to 600 grit) performed prior to the pre-oxidation, it has also been observed by other researchers [11,15]. Fig.…”
Section: Conductivity (S/cm) Hsupporting
confidence: 55%
“…Caré et al [42] found that the elastic modulus of rust was not constant but rather would increase with time. Hosemann et al [43] developed nano-indentation tests on the rust samples and showed that the range of elastic modulus values was 70-100 GPa. Bhargava et al [2,10] took the effective elastic modulus of the steel-rust product composites as 210 GPa which is the same as that of reinforcement.…”
Section: Deformation Compatibility and Force Equilibrium In The Radiamentioning
confidence: 99%
“…Micro pillars could be cut from the original sample and placed on an "anvil" and transported to a nanoindenter and tested. In this and previous work [6,13] it has been shown that a sample of 8×8×16 μm is sufficient to perform micro mechanical tests on irradiated F/M materials. Using this volume as a comparison point, one micro pillar cut from a STIP tensile sample has 2.55 Bq which is again just below background levels.…”
Section: Figmentioning
confidence: 58%
“…HT-9 is considered for in core structural components in the USA because of its substantial dataset on radiation induced property changes [2][3][4][5]. In addition, the performance of HT-9 in contact with lead bismuth eutectic coolants has been examined in relevant fast reactors environments [6,7]. After the actual STIP irradiation the samples were stored for a period of 62 month in order to allow for a decay of the shorter lived isotopes.…”
Section: Introductionmentioning
confidence: 99%