2022
DOI: 10.1016/j.ultrasmedbio.2022.02.018
|View full text |Cite
|
Sign up to set email alerts
|

Nanodroplet-Mediated Low-Energy Mechanical Ultrasound Surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

6
2

Authors

Journals

citations
Cited by 17 publications
(12 citation statements)
references
References 43 publications
0
12
0
Order By: Relevance
“…Introducing cavitation nuclei can help to reduce the energy threshold for cavitation and enhance the therapeutic outcome significantly [12] . In recent years, the acoustically sensitive perfluorocarbon (PFC) nanodroplets as small as a few hundreds of nanometers have attractively emerged as an alternative to conventional microbubbles in the enhanced HIFU treatment and ultrasound imaging due to their longer circulation lifetime and smaller size for significant enhanced permeability and retention (EPR) effects in vivo relative to microbubbles [13] .…”
Section: Introductionmentioning
confidence: 99%
“…Introducing cavitation nuclei can help to reduce the energy threshold for cavitation and enhance the therapeutic outcome significantly [12] . In recent years, the acoustically sensitive perfluorocarbon (PFC) nanodroplets as small as a few hundreds of nanometers have attractively emerged as an alternative to conventional microbubbles in the enhanced HIFU treatment and ultrasound imaging due to their longer circulation lifetime and smaller size for significant enhanced permeability and retention (EPR) effects in vivo relative to microbubbles [13] .…”
Section: Introductionmentioning
confidence: 99%
“…Importantly, both steps were carried out while operating below an MI of 1.9, in accordance with Food and Drug Administration (FDA) guidelines and reduce the pressure threshold required for standard histotripsy by two orders of magnitude. There are two major differences compared to previous work 38 . First, a 1D fixed imaging array was previously used for ND activation.…”
Section: Introductionmentioning
confidence: 73%
“…The MB expansion ratio, defined as the maximal diameter divided by the resting MB diameter, was evaluated for a center frequency of 250 kHz and peak negative pressures (PNP) ranging from 0 to 800 kPa. The simulation parameters were described previously ( Glickstein et al, 2022 ). The initial MB resting diameter was set to 1.5 μm.…”
Section: Methodsmentioning
confidence: 99%
“…1 . This effect was recently shown to facilitate the delivery of large genes into cancer cells ( Ilovitsh et al, 2020 ), and for low energy mechanical ablation of tumors ( Bismuth et al, 2021 ; Glickstein et al, 2022 ). Given the advantages of low frequency insonation, and the growing interest in the use of low frequencies ( Ilovitsh et al, 2020 ; Bai et al, 2016 ; Zhang et al, 2021 ), there is a crucial need for studies on ways to optimize the relationship between molecule size and delivery efficacy upon low frequency sonoporation for effective drug delivery.…”
Section: Introductionmentioning
confidence: 99%