2022
DOI: 10.1016/j.chroma.2022.463269
|View full text |Cite
|
Sign up to set email alerts
|

Nanoflow liquid chromatography mass spectrometry method for quantitative analysis and target ion screening of pyrrolizidine alkaloids in honey, tea, herbal tinctures, and milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 23 publications
0
10
0
Order By: Relevance
“…The solvents used were LLE and SALLE, and the clean-up sorbents included anhydrous magnesium sulfate (MgSO 4 ), sodium chloride (NaCl), and primary-secondary amine (PSA). A QuEChERS-based extraction procedure involving acetonitrile, NaCl, MgSO 4 , sodium citrate, and sodium citrate tribasic clean-up sorbents has been applied for the extraction and analysis of PAs/PANOs in honey and oregano [39,56]. Izcara et al (2020) presented the development of a miniaturized strategy based on the QuEChERS method combined with UHPLC-MS/MS for the determination of 21 PAs suggested by the European Food Safety Authority.…”
Section: Pas Extraction and Detection Methodsmentioning
confidence: 99%
“…The solvents used were LLE and SALLE, and the clean-up sorbents included anhydrous magnesium sulfate (MgSO 4 ), sodium chloride (NaCl), and primary-secondary amine (PSA). A QuEChERS-based extraction procedure involving acetonitrile, NaCl, MgSO 4 , sodium citrate, and sodium citrate tribasic clean-up sorbents has been applied for the extraction and analysis of PAs/PANOs in honey and oregano [39,56]. Izcara et al (2020) presented the development of a miniaturized strategy based on the QuEChERS method combined with UHPLC-MS/MS for the determination of 21 PAs suggested by the European Food Safety Authority.…”
Section: Pas Extraction and Detection Methodsmentioning
confidence: 99%
“…An unstable electrospray leads to decreased signal intensities and droplet formation at the emitter tip, which affects the sensitivity and applicability of the method. Several approaches to improve nano-electrospray stability have been described, such as post-column solvent addition [27,28], where a highly organic solvent is continuously added to the column eluate via a T-piece to reduce the aqueous phase content and facilitate electrospray, voltage regulation during analysis [29], and selection of the correct nano-ESI voltage. In this work, optimal nano-electrospray performance was achieved by manually selecting a suitable voltage in a range of 1.70-2.50 kV for both positive and negative modes under initial gradient conditions, and the optimal voltages that provided the most stable nano-electrospray were used.…”
Section: Optimisation Of the Orbitrap Ms Parametersmentioning
confidence: 99%
“…It is essential to define national food resource characteristics. First, we must be aware of whether the composition comes with health benefits [49] or risks [50]. Second, product screening at the national level is significant if the characteristics are outstanding in the international context; put simply-if the food is outstanding.…”
Section: Polyfloral Honey Element Chemical Profilementioning
confidence: 99%