1998
DOI: 10.1016/s0925-4005(98)00128-2
|View full text |Cite
|
Sign up to set email alerts
|

Nanoscaled interdigitated electrode arrays for biochemical sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
141
0

Year Published

2001
2001
2018
2018

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 362 publications
(153 citation statements)
references
References 6 publications
6
141
0
Order By: Relevance
“…These are dependent on the electrode material and the electrolyte solution [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15], but for horizontal electrode surfaces they can be approximated by…”
Section: Equivalent Circuit Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…These are dependent on the electrode material and the electrolyte solution [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15], but for horizontal electrode surfaces they can be approximated by…”
Section: Equivalent Circuit Modelmentioning
confidence: 99%
“…These electrode arrays have become more prominent as a sensor device due to the ongoing miniaturization of electrodes and the low cost of these systems [5]. An important advantage of these sensors is its simple and inexpensive mass-fabrication process and the ability to use them over a wide range of applications without significant changes in the sensor design [6][7]. Another potential benefit is the ability to integrate electrodes with instrumentation to develop autonomous, lab-on-chip measurement systems.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, microfabricated interdigitated array (IDA) microelectrodes have received great attention in the areas of impedimetric immunosensing and biosensing (Van Gerwen et al, 1998;Laureyn et al, 1999aLaureyn et al, ,b, 2000, and impedance measurement for studies of biological cell behaviors (Ehret et al, 1997(Ehret et al, , 1998). …”
Section: Interdigitated Array Microelectrodes (Idas) In Impedance Meamentioning
confidence: 99%
“…Several studies have shown that IDA microelectrodes have great promises in the field of label-free impedimetric biosensing (Laureyn et al, 1999a,b;Van Gerwen et al, 1998). The IDA microelectrodes are capable of monitoring the changes of the electrical properties in the immediate neighborhood of their surfaces.…”
Section: Electrochemical Impedance Biosensors Using Redox Probesmentioning
confidence: 99%
See 1 more Smart Citation