2009
DOI: 10.1053/j.gastro.2008.10.022
|View full text |Cite
|
Sign up to set email alerts
|

Narrow-Band Versus White-Light High Definition Television Endoscopic Imaging for Screening Colonoscopy: A Prospective Randomized Trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
124
0
10

Year Published

2010
2010
2016
2016

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 184 publications
(140 citation statements)
references
References 37 publications
6
124
0
10
Order By: Relevance
“…The ADR of 62% using the water with indigo carmine method was higher than those derived from studies using other modalities, even those obtained with high definition colonoscopes 15,[21][22][23] , narrow band imaging (NBI) 24,27,28 or dye spray chromoendoscopy [35][36][37] . Conventional targeted dye-spray chromoendoscopy has been reported to require up to an average of 33 minutes in total procedure time 13 , 26 minutes in withdrawal time 10 , or a median withdrawal time of 25 minutes (range 8 -153 min) 37 .…”
Section: Discussionmentioning
confidence: 87%
See 1 more Smart Citation
“…The ADR of 62% using the water with indigo carmine method was higher than those derived from studies using other modalities, even those obtained with high definition colonoscopes 15,[21][22][23] , narrow band imaging (NBI) 24,27,28 or dye spray chromoendoscopy [35][36][37] . Conventional targeted dye-spray chromoendoscopy has been reported to require up to an average of 33 minutes in total procedure time 13 , 26 minutes in withdrawal time 10 , or a median withdrawal time of 25 minutes (range 8 -153 min) 37 .…”
Section: Discussionmentioning
confidence: 87%
“…Distal = distal to the splenic flexure. definition, wide-angle endoscope 15,[21][22][23][24][25] ; narrow band imaging [26][27][28] ; transparent hood attached to the tip of the colonoscope 26,29,30 withdrawal time >6 min 31,32 or modified (e.g. split-dose) bowel preparation 33,34 .…”
Section: Discussionmentioning
confidence: 99%
“…NBI is expected to result in better detection of colorectal adenomas and better distinction between neoplasms and nonneoplastic lesions. Recently, although several investigators in western countries have been trying to demonstrate its ability to detect colorectal adenomas, most randomized trials have reported negative results (Adler et al, 2008(Adler et al, , 2009). On the other hands, Japanese investigators have reported positive results in their articles (Inoue et al, 2008;Uraoka et al, 2008).…”
Section: Optical Methods For Minimizing the Overlooking Of Colorectalmentioning
confidence: 99%
“…The reasons for missed polyps included the quality of bowel preparation, lesion characteristics (location, number, shape, and size), the endoscopist's experience, and the operator's insertion and withdrawal techniques [41][42][43][44]. Although many clinical studies, including randomized controlled trials (RCTs), have confirmed reduced missed rates in colonoscopy using NBI techniques [45][46][47][48][49][50][51][52], one recent meta-analysis revealed that there was no statistically significant difference in the rates of adenoma detection rate between NBI and WL [53], and a large-scale multicenter Japanese study did not show an improvement with NBI [54]. Moreover, another systematic review including 8 RCTs showed that NBI did not improve detection of colorectal polyps when compared to WL [55].…”
Section: Adenoma Detection Ratementioning
confidence: 99%