SummaryLaryngoscopy can induce stress responses that may be harmful in susceptible patients. We directly measured the force applied to the base of the tongue as a surrogate for the stress response. Force measurements were obtained using three FlexiForce Sensors Ò (Tekscan Inc, Boston, MA, USA) attached along the concave surface of each laryngoscope blade.Twenty-four 24 adult patients of ASA physical status 1-2 were studied. After induction of anaesthesia and neuromuscular blockade, laryngoscopy and tracheal intubation was performed using either a Macintosh or a GlideScope (93-207 [17-509]) Ns; p = 0.017) with the GlideScope. Our study shows that the peak lifting force on the base of the tongue during laryngoscopy is less with the GlideScope videolaryngoscope compared with the Macintosh laryngoscope.