2005
DOI: 10.1038/sj.eye.6701778
|View full text |Cite
|
Sign up to set email alerts
|

National Biometry Audit II

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
19
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 24 publications
(23 citation statements)
references
References 9 publications
4
19
0
Order By: Relevance
“…A study of 22 paediatric eyes undergoing 17 although it is acknowledged that immersion ultrasonography requires skill and experience 18 and is not available in many units in the United Kingdom. 19 When using A-scan ultrasound, the speed of the ultrasound waves is affected by the density of the material through which it is passing. Very dense cataracts may influence the final measurement to a greater extent in shorter eyes as the lens makes up a relatively greater proportion of the axial length.…”
Section: Discussionmentioning
confidence: 99%
“…A study of 22 paediatric eyes undergoing 17 although it is acknowledged that immersion ultrasonography requires skill and experience 18 and is not available in many units in the United Kingdom. 19 When using A-scan ultrasound, the speed of the ultrasound waves is affected by the density of the material through which it is passing. Very dense cataracts may influence the final measurement to a greater extent in shorter eyes as the lens makes up a relatively greater proportion of the axial length.…”
Section: Discussionmentioning
confidence: 99%
“…1,8 Customisation of A constants for an intraocular lens is important to eliminate systemic errors that may occur due to the differences in the method of axial length measurement or due to sub-optimal manufacturer's A constants. For the same intraocular lens (IOL), when using PCI compared with acoustic methods of axial length measurement there can be more than 1 D of difference between customised A constants.…”
Section: Discussionmentioning
confidence: 99%
“…2,6,7 Setting a benchmark standard would allow all National Health Service (NHS) cataract services to know whether they are achieving a satisfactory standard. It has previously been suggested, 1,8 based upon studies, [3][4][5][6] that a benchmark of 85-90% of patient undergoing routine cataract surgery should achieve a final spherical equivalent refraction within 1 D of the predicted value.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…7,14 For these eyes ultrasonic axial length measurement is required, and in the UK contact ultrasound is the method of choice with immersion methods rarely used. 15 In general, however, immersion ultrasound produces more accurate predictions than contact ultrasound, 8 approaching or matching those of the optical methods. 16,17 If immersion ultrasound was adopted as the second-line investigation for eyes in which optical biometry fails, then outcomes could be improved from 82.5% within ± 1 D of target 10 to between 85.7 and 94.3%.…”
Section: Axial Length Measurementmentioning
confidence: 99%