“…Figure 1a depicts a typical radiographic setup (in place at ANL's X-ray Computed Tomography laboratory) with an example X-ray beam emanating from the X-ray tube (source), passing through the object, and then incident onto the recording medium. According to Beer's law (see above), the intensity of the X-rays incident onto the recording medium is proportional to their number and energy, depends on how much they have been attenuated by the modities and machine components (Ellingson et al, 1997;Liaptsis et al, 2010;Mei et al, 2007;Sun et al, 2008). See Hellier 2012, as well as the journals Research in Nondestructive Evaluation, Nondestructive Testing and Evaluation, and the Journal of Nondestructive Evaluation for an introduction to this materials analytical sub-eld.…”
Section: Basic Principles Of X-radiographic Physicsmentioning
confidence: 99%
“…Figure 1a depicts a typical radiographic setup (in place at ANL's X-ray Computed Tomography laboratory) with an example X-ray beam emanating from the X-ray tube (source), passing through the object, and then incident onto the recording medium. According to Beer's law (see above), the intensity of the X-rays incident onto the recording medium is proportional to their number and energy, depends on how much they have been attenuated by the modities and machine components (Ellingson et al, 1997;Liaptsis et al, 2010;Mei et al, 2007;Sun et al, 2008). See Hellier 2012, as well as the journals Research in Nondestructive Evaluation, Nondestructive Testing and Evaluation, and the Journal of Nondestructive Evaluation for an introduction to this materials analytical sub-eld.…”
Section: Basic Principles Of X-radiographic Physicsmentioning
confidence: 99%
“…Further, radiographic testing was also proven not to be sensitive to density variations, whereas ultrasonic techniques were able to determine sensitive density variations. 4 Experimental Procedure…”
Section: Introductionmentioning
confidence: 99%
“…Attempts have been made by several authors to estimate bulk density values of ceramic components. Limited work has been carried out in showing the local density variation across an entire ceramic component, especially in reaction‐formed sintered SiC ceramics.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations