2000
DOI: 10.1006/abio.2000.4768
|View full text |Cite
|
Sign up to set email alerts
|

Near-Infrared Spectrophotometric Determination of Tri- and Tetrapeptides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
11
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 15 publications
(11 citation statements)
references
References 11 publications
0
11
0
Order By: Relevance
“…These can be attributed to the overtone and combination transition of the –OH groups. Since CS also possesses the same O-H groups in addition to N-H 2 group, NIR spectra of CS powder and film (4D) also have additional bands at around 1548nm and 2028nm which expectedly can be attributed to the –NH modes [57–60]. The similarity between the NIR spectra of starting polysaccharides and regenerated polysaccharide further confirms that CEL and CS were successfully regenerated by this preparation method.…”
Section: Resultsmentioning
confidence: 76%
See 1 more Smart Citation
“…These can be attributed to the overtone and combination transition of the –OH groups. Since CS also possesses the same O-H groups in addition to N-H 2 group, NIR spectra of CS powder and film (4D) also have additional bands at around 1548nm and 2028nm which expectedly can be attributed to the –NH modes [57–60]. The similarity between the NIR spectra of starting polysaccharides and regenerated polysaccharide further confirms that CEL and CS were successfully regenerated by this preparation method.…”
Section: Resultsmentioning
confidence: 76%
“…NIR spectra were taken on a home-built NIR spectrometer based on an acoustooptic tunable filter. Information on this NIR spectrometer was described in detail in our previous papers [45, 46]. Normally, each spectrum was an average of 30 spectra taken at 1-nm intervals from 1450 to 2450 nm.…”
Section: Methodsmentioning
confidence: 99%
“…27,28 FT-IR spectra were measured on a PerkinElmer 100 spectrometer at 2 cm −1 resolution with either KBr or by a ZnSe single reflection ATR accessory (Pike Miracle ATR). X-ray diffraction (XRD) measurements were taken on a Rigaku MiniFlex II diffractometer equipped with a Cu Kα source.…”
Section: Methodsmentioning
confidence: 99%
“…Such a spectrometer was successfully constructed in our laboratory using the acoustooptic tunable lter. [25][26][27] An acousto-optic tunable lter (AOTF) is an all-solidstate, electronic dispersive device that is based on the diffraction of light by acoustic waves in an anisotropic crystal. [28][29][30] The wavelength of the diffracted light is dependent on the frequency and the power of the applied acoustic wave.…”
mentioning
confidence: 99%