2015
DOI: 10.1103/physrevstab.18.080101
|View full text |Cite
|
Sign up to set email alerts
|

Negative ion beam space charge compensation by residual gas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(18 citation statements)
references
References 9 publications
0
18
0
Order By: Relevance
“…To better understand the remarkable lifetime improvement observed using the biased anode, the anode-cathode gap and a portion of the adjacent beam line were modeled using the ion beam simulator code, IBSIMU [38], which is a powerful suite of libraries based on C++ programming language for low-energy particle tracking in electric and magnetic fields. The open source distribution code has been utilized in the design of ion sources [39,40]. IBSIMU is designed for unbunched (dc) beams only.…”
Section: Ion Production and Its Effect On Photocathode Lifetimementioning
confidence: 99%
“…To better understand the remarkable lifetime improvement observed using the biased anode, the anode-cathode gap and a portion of the adjacent beam line were modeled using the ion beam simulator code, IBSIMU [38], which is a powerful suite of libraries based on C++ programming language for low-energy particle tracking in electric and magnetic fields. The open source distribution code has been utilized in the design of ion sources [39,40]. IBSIMU is designed for unbunched (dc) beams only.…”
Section: Ion Production and Its Effect On Photocathode Lifetimementioning
confidence: 99%
“…Under the auspices of BEAM three students have obtained a Ph.D. in accelerator sciences. In addition to the work on electron cloud effects, they have also contributed to our current knowledge on Crab cavities [6] and the design and construction of the LINAC4 [7]. Also three students got their M. Sc.…”
Section: The Collaboration With Cernmentioning
confidence: 96%
“…One can argue that the maximum allowable perveance with lumped focusing corresponds to the case when the minimum practical physical distance between lenses exceeds their length by only a factor of 2-3 (with a factor of '1' meaning that the lenses would be touching). Then, taking a factor of 3 for the lenses' distance-to-length ratio implies _ ≅ 12 (4) and the maximum allowable perveance is…”
Section: Ii1 Linear Space Charge Effectmentioning
confidence: 99%