1994
DOI: 10.1049/ip-cds:19941190
|View full text |Cite
|
Sign up to set email alerts
|

Neural network for pattern association in electrical capacitance tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
21
0

Year Published

1997
1997
2013
2013

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 0 publications
0
21
0
Order By: Relevance
“…This has led to inaccurate oil fraction estimations. Since then, researchers have keenly developed various image reconstruction algorithms such as the Landweber [ 32 34 ] and Tikhonov [ 19 , 23 , 35 ] algorithms to produce better tomograms. Research works in image-based ECT measurement using an Artificial Neural Network (ANN) have also been carried out to improve the inaccuracy of the tomograms.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This has led to inaccurate oil fraction estimations. Since then, researchers have keenly developed various image reconstruction algorithms such as the Landweber [ 32 34 ] and Tikhonov [ 19 , 23 , 35 ] algorithms to produce better tomograms. Research works in image-based ECT measurement using an Artificial Neural Network (ANN) have also been carried out to improve the inaccuracy of the tomograms.…”
Section: Introductionmentioning
confidence: 99%
“…Research works in image-based ECT measurement using an Artificial Neural Network (ANN) have also been carried out to improve the inaccuracy of the tomograms. The work by Noralahiyan et al has shown that it is feasible to use the ANN technique to reconstruct more accurate images [ 23 – 26 ], however, the image reconstruction process is time consuming due to the requirement for intensive computations of hundreds of image pixels and hence, it is only suitable for offline data processing [ 27 ].…”
Section: Introductionmentioning
confidence: 99%
“…The ANN is a proven functional method for ECT image reconstruction. Several worldwide researchers have already reported promissory results by using this technique [8] [9] [11]. Experiments displayed in this paper have reached 0.24 maximum error image results.…”
Section: Discussionmentioning
confidence: 56%
“…The relationship between capacitance measurement values and pixel points of reconstruction image is described in Figure 4 [5], where the left is ECT capacitance transducers and the right is reconstruction image field.…”
Section: Design Of Input Layer and Output Layermentioning
confidence: 99%