Reactor Dosimetry in the 21st Century 2003
DOI: 10.1142/9789812705563_0036
|View full text |Cite
|
Sign up to set email alerts
|

Neutron and Gamma Fluence and Radiation Damage Parameters of Ex-Core Components of Russian and German Light Water Reactors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

6
11
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(17 citation statements)
references
References 3 publications
6
11
0
Order By: Relevance
“…In addition, the gamma fluence was about one order higher than the relative neutron fluence, mainly because of the (n,γ) reaction of neutron with the iron composition in the vessel. Table III compared the results of neutron flux integrals onthe core mid-plane between our MCNP5 calculations and those reported in [2]. As shown in this Table, the difference in the MCNP5 and BUGLE-96 values could reach about 25% at the outer surface of the RPV.…”
Section: Calculation Resultsmentioning
confidence: 78%
See 2 more Smart Citations
“…In addition, the gamma fluence was about one order higher than the relative neutron fluence, mainly because of the (n,γ) reaction of neutron with the iron composition in the vessel. Table III compared the results of neutron flux integrals onthe core mid-plane between our MCNP5 calculations and those reported in [2]. As shown in this Table, the difference in the MCNP5 and BUGLE-96 values could reach about 25% at the outer surface of the RPV.…”
Section: Calculation Resultsmentioning
confidence: 78%
“…As shown in this Table, the difference in the MCNP5 and BUGLE-96 values could reach about 25% at the outer surface of the RPV. The reason might be due to the discrepancy between our reactor core input data and those used in [2]. Namely, different core loading pattern, fuel assemblies, steel baffle, and water hole data were used in this calculation.…”
Section: Calculation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Three-dimensional (3-D) synthesis method based on results of DORT calculations was used for neutron fluence rate evaluations [4]. Analytical justification of 3-D synthesis method by comparison with precise 3-D calculations based on Monte Carlo codes was carried out [5]. The calculation procedure based on code DORT applies routinely for RPV neutron fluence evaluation with the purpose of estimation of RPV lifetime.…”
Section: A Calculational Proceduresmentioning
confidence: 99%
“…Three-dimensional (3D) synthesis method based on results of DORT calculations was used for neutron fluence rate evaluations [4]. Analytical justification of 3D synthesis method by comparison with precise 3D calculations based on Monte Carlo codes was carried out [5]. The calculation procedure based on code DORT applies routinely for RPV neutron fluence evaluation with the purpose of estimation of RPV lifetime.…”
Section: A Calculational Proceduresmentioning
confidence: 99%