1999
DOI: 10.1103/physreve.59.5577
|View full text |Cite
|
Sign up to set email alerts
|

Neutron reflectivity studies of critical adsorption: The correspondence between a critical adsorption profile and specular neutron reflection

Abstract: For interfacial order parameter profiles which decay as Az(-mu), such as the composition profile of the noncritical interface of a binary liquid mixture at a critical end point, there is a reported one-to-one correspondence between the profile and the reflectivity which can be described by an analytical theory [S. Dietrich and R. Schack, Phys. Rev. Lett. 58, 140 (1987)]. Evidence for mu=0.53+/-0.02 for adsorption at the hydrophilic silicon/liquid surface of the mixture (2-butoxyethanol+deuterium oxide) near it… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 14 publications
1
6
0
Order By: Relevance
“…For all X-ray measurements, the sample was kept under an inert argon atmosphere in a home-built container with a 0.025 mm thick Kapton HN window (DuPont, Hamm, Germany). Details on the home-built X-ray instrument and its operational modes can be found elsewhere …”
Section: Experimental Sectionmentioning
confidence: 99%
See 1 more Smart Citation
“…For all X-ray measurements, the sample was kept under an inert argon atmosphere in a home-built container with a 0.025 mm thick Kapton HN window (DuPont, Hamm, Germany). Details on the home-built X-ray instrument and its operational modes can be found elsewhere …”
Section: Experimental Sectionmentioning
confidence: 99%
“…Details on the home-built X-ray instrument and its operational modes can be found elsewhere. 18 In Situ Neutron Reflectometry. NR measurements were performed at the time-of-flight (TOF) reflectometer BioRef (V18) at the Helmholtz-Zentrum Berlin (HZB).…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…All X-ray reflectivity experiments were performed at ambient humidity at room temperature. Details on the home-built instrument and its operational mode can be found elsewhere …”
Section: Methodsmentioning
confidence: 91%
“…Details on the home-built instrument and its operational mode can be found elsewhere. 30 Analysis of X-ray Reflectivity Data. During the optimization of the sample preparation, the influence of different parameters was investigated.…”
Section: ■ Experimental Sectionmentioning
confidence: 99%
“…Besides their interest as regards basic science, such phenomena are of importance in many applications fields like those of colloids, metallurgy, chemical synthesis in unusual systems (microdivided systems, supercritical fluids), heterogeneous catalysis and petroleum recovery. So, in addition to precise elegant laws like the critical divergence of adsorption or the critical coexistence curve equation [7][8][9], it is also of great interest to examine the general behaviour of adsorption in relation to wetting in a phase diagram that is as complete as possible. This behaviour also allows one to detect possible phenomena that are more minute than critical behaviours and related divergences like prewetting [10].…”
Section: Introductionmentioning
confidence: 99%