2012
DOI: 10.1111/ijlh.12002
|View full text |Cite
|
Sign up to set email alerts
|

Neutrophil volume, conductivity and scatter parameters with effective modeling of molecular activity statistical program gives better results in neonatal sepsis

Abstract: We suggest to use the combination of MNV and VDW with markers such as CRP and IL-6, and use diagnostic models created by EMMA.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
10
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 16 publications
1
10
0
Order By: Relevance
“…Celik et al . suggested models using a combination of C‐reactive protein, the mean and standard deviation of neutrophil volume, and interleukin 6 levels for screening for sepsis.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Celik et al . suggested models using a combination of C‐reactive protein, the mean and standard deviation of neutrophil volume, and interleukin 6 levels for screening for sepsis.…”
Section: Introductionmentioning
confidence: 99%
“…Cell population data distributions are reported to be of some value in screening for infection or sepsis, both in adults and in children [1][2][3][4]. Most of the studies on such screening have focused on neutrophils, because these play the major role in immune responses against bacterial infections along with phagocytic and enzymatic bacterial destruction via lysosomes [1][2][3][4][5][6][7][8][9]. The mean neutrophil volume, standard deviation of neutrophil volume, and neutrophil conductivity are all increased in patients with infections [1][2][3][4][5][6][7]9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Automated hematology analyzers yield several electronic and optical leukocyte indices like volumes of leukocyte subsets, cellular electrical conductivity, optical light scatter, etc. These have shown promise in early and sensitive diagnosis of diseases characterized by leukocytic abnormalities [3,[5][6][7][8][9]. The leukocyte differential in Beckman Coulter analyzers (Beckman Coulter, Miami, FL, USA) is based on VCS technology (volume, conductivity, and scatter) that quantifies leukocyte cell volume by voltage impedance (V); cytoplasmic and nuclear density by radio frequency conductivity (C); and cytoplasmic granularity and nuclear complexity by laser light scatter (S) [3].…”
mentioning
confidence: 99%
“…Using the percentages calculated by the automated cell counter (Beckman Coulter LH780 Analyzer, Beckman Coulter Inc. Diagnostic Division Headquarters, CA, USA) we determined the differentiated neutrophil and lymphocyte counts (11).…”
mentioning
confidence: 99%